Kirihigashi K, Tatsumi N, Hino M, Yamane T, Ohta K
Department of Clinical and Laboratory Medicine, Osaka City University Medical School, Japan.
Osaka City Med J. 2000 Jun;46(1):55-70.
An enzymatic bilirubin assay using bilirubin oxidase was evaluated. Its repeatability and linearity were excellent, and excellent correlations were observed between the enzyme and the diazo methods in total and conjugated bilirubin. The coefficient of correlation between the conjugated bilirubin fraction obtained with the diazo method and that of HPLC was 0.424, while this coefficient was 0.580 for the diazo method. A multi-laboratory study using 3 serum specimens revealed lower coefficients of variation for the enzymatic method than for the diazo method. Bilirubinuria specimen showed good accord between total bilirubin and conjugate bilirubin levels for the enzymatic method, not for the diazo method. When 12 newborn baby specimens and 34 pediatric specimens were studied, all exhibited increased concentrations of conjugated bilirubin with the diazo method. In an adult case with prolonged jaundice, the diazo method usually yielded higher conjugated bilirubin values than the enzymatic method. The enzymatic method was then concluded to be superior to the diazo method for conjugated bilirubin determination.
对一种使用胆红素氧化酶的酶法胆红素测定进行了评估。其重复性和线性极佳,并且在总胆红素和结合胆红素方面,该酶法与重氮法之间观察到了良好的相关性。用重氮法获得的结合胆红素部分与高效液相色谱法的结合胆红素部分之间的相关系数为0.424,而重氮法自身的该系数为0.580。一项使用3份血清标本的多实验室研究显示,酶法的变异系数比重氮法更低。胆红素尿标本显示,酶法的总胆红素和结合胆红素水平之间吻合良好,而重氮法并非如此。当研究12份新生儿标本和34份儿科标本时,重氮法显示所有标本的结合胆红素浓度均升高。在一例成人长期黄疸病例中,重氮法通常产生的结合胆红素值高于酶法。由此得出结论,在结合胆红素测定方面,酶法比重氮法更具优势。