Suppr超能文献

用于监测酶联免疫吸附测定(ELISA)法检测抗锥虫抗体操作性能的图表绘制方法。

Charting methods to monitor the operational performance of ELISA method for the detection of antibodies against trypanosomes.

作者信息

Rebeski D E, Winger E M, Ouma J O, Kong Pages S, Büscher P, Sanogo Y, Dwinger R H, Crowther J R

机构信息

Animal Production Unit, Food and Agriculture Organisation/International Atomic Energy Agency, Agriculture and Biotechnology Laboratory, International Atomic Energy Agency, PO Box 100, A-1400 Vienna, Austria.

出版信息

Vet Parasitol. 2001 Mar 5;96(1):11-50. doi: 10.1016/s0304-4017(00)00422-2.

Abstract

Four indirect enzyme-linked immunosorbent assays (ELISAs) for the detection of antibody against trypanosomes using antigen-precoated plates (Trypanosoma congolense and T. vivax) were used in 15 veterinary diagnostic laboratories in Africa and Europe. The study provided data allowing an evaluation of charting methods with respect to the operational performance of each ELISA. Data from standardised internal quality control (IQC) samples were plotted on charts and used as the assay performance indicators with reference to expected upper and lower control limits. Based on unprocessed (optical density) and normalised absorbance values (calculated as a percentage positivity of a control), dispersion of values from the expected data range was estimated plotting the location and deviation of the values. In addition, assay precision was estimated plotting the distribution of coefficients of variation<10% of the IQCs. Binding ratios of controls were calculated to estimate the assay proficiency with respect to the accuracy of assessing that the IQC samples tested positive or negative in the test proper. The graphical analysis of dispersion of absorbance values in combination with assay precision and proficiency criteria was considered fully satisfactory to evaluate the operational performance of the ELISAs and provided useful decision criteria for plate acceptance and rejection. The establishment of standardised and transparent IQC data charting methods for the indirect ELISAs provided an increased measure of confidence to national laboratories with respect to their reports on disease occurrence. Moreover, the relative assay performances between all laboratories were examined using summary data charts with reference to the performance criteria described. The IQC data were also examined using modified Youden plot analysis demonstrating that indirect ELISA methods can be successfully applied at diagnostic laboratories in the tropics for monitoring trypanosomosis control programmes.

摘要

在非洲和欧洲的15个兽医诊断实验室中,使用了四种间接酶联免疫吸附测定法(ELISA),通过预包被抗原的酶标板(刚果锥虫和活泼锥虫)来检测锥虫抗体。该研究提供的数据可用于评估每种ELISA的操作性能的制图方法。将标准化内部质量控制(IQC)样本的数据绘制在图表上,并用作参考预期上下控制限的测定性能指标。基于未处理的(光密度)和标准化吸光度值(计算为对照的阳性百分比),通过绘制值的位置和偏差来估计预期数据范围的值的离散度。此外,通过绘制变异系数分布(<IQC的10%)来估计测定精密度。计算对照的结合率,以评估在正确测试中IQC样本检测为阳性或阴性的准确性方面的测定熟练度。吸光度值离散度的图形分析与测定精密度和熟练度标准相结合,被认为完全令人满意,可用于评估ELISA的操作性能,并为酶标板的接受和拒收提供有用的决策标准。为间接ELISA建立标准化和透明的IQC数据制图方法,提高了国家实验室对其疾病发生报告的信心。此外,使用汇总数据图表,参照所述的性能标准,检查了所有实验室之间的相对测定性能。还使用改良的尤登图分析对IQC数据进行了检查,结果表明间接ELISA方法可成功应用于热带地区的诊断实验室,以监测锥虫病控制计划。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验