Laganá A, Fago G, Marino A, Santarelli D
Department of Chemistry, 'La Sapienza' University, Piazzale Aldo Moro 5, 00185 Roma, Italy.
Rapid Commun Mass Spectrom. 2001;15(4):304-10. doi: 10.1002/rcm.223.
An analytical procedure that enables routine analysis for trace determination of six anabolic macrocyclic lactones (zearalenone, alpha- and beta-zearalenol, zearalanone, zeranol, and taleranol) in sewage treatment plant (STP) samples has been developed. The method uses solid-phase extraction, followed by high-performance liquid chromatography with on-line tandem mass spectrometry using atmospheric pressure chemical ionization (LC/APCI-MS/MS). The extraction of these compounds from filtered water samples was performed off-line with C(18) solid-phase cartridges. The detection was achieved by isocratic reversed-phase high-performance liquid chromatography coupled with an heated nebulizer (HN) APCI interface operating in negative ion mode. Mean recovery of the analytes in STP effluent samples generally exceeded 81%. This method was used to determine the occurrence of target analytes in the aquatic environment. In the selected STP effluent samples, zearalenone and alpha-zearalenol were detected in the ng/L range.