Contreras C C, Beraquet N J
Centro de Tecnologia de Carnes, Instituto de Tecnologia de Alimentos, Campinas, SP, Brazil.
Poult Sci. 2001 Apr;80(4):501-7. doi: 10.1093/ps/80.4.501.
The first experiment was conducted to determine the effects of varying voltage, 20, 40, 80, and 100 V at 60 Hz, on stunning efficiency, blood loss, and carcass defects. In the second experiment, the same parameters were evaluated to determine the effects of varying frequency, 60, 200, 350, 500, and 1,000 Hz at 40 V. A control group for both experiments was not stunned. At 40V, 30 to 50 mA, 90% of the birds were unconscious, as shown by no response to comb piercing, and blood loss was maximized (55.3%). When varying the stunning frequency, maximum blood loss (73.1%), 90% of the birds were unconscious, and minimum carcass defects were observed at 1,000 Hz, 40 V. In the third experiment, birds were stunned at 40 V, 1,000 Hz and deboned immediately after defeathering (hot boning) and chilled or deboned after passing through all stages of a commercial abattoir operation (conventional boning). Control lots were unstunned and followed normal abattoir stages. Average shear value was significantly lower for stunned compared to unstunned birds (6.0 vs. 7.1 kg/g), although tenderness scores, as measured by a trained panel, were not significantly different (6.6 for stunned birds vs. 6.1 for unstunned). Scores for juiciness were also not significantly different (5.5 for stunned vs. 5.8 for unstunned). Average shear value was also significantly lower for conventionally boned birds (5.2 kg/g) than for hot boned birds (7.9 kg/g). Sensory analysis confirmed the shear value results. Conventionally boned breasts had an average tenderness score of 7.4 vs. an average of 5.3 for hot boned breast. No statistical differences were observed with respect to juiciness, although a score of 6.2 was observed for conventionally boned breast meat vs. a score of 5.1 for hot boned breast meat.
第一个实验旨在确定在60赫兹下,20伏、40伏、80伏和100伏的不同电压对致昏效率、失血情况和胴体缺陷的影响。在第二个实验中,评估相同参数以确定在40伏下,60赫兹、200赫兹、350赫兹、500赫兹和1000赫兹的不同频率的影响。两个实验均设有未致昏的对照组。在40伏、30至50毫安时,90%的禽类失去意识,表现为对鸡冠穿刺无反应,且失血量最大(55.3%)。当改变致昏频率时,在1000赫兹、40伏时观察到最大失血量(73.1%),90%的禽类失去意识,且胴体缺陷最少。在第三个实验中,禽类在40伏、1000赫兹下致昏,脱毛后立即去骨(热去骨),或在经过商业屠宰场的所有操作阶段后去骨(常规去骨)并冷藏。对照组未致昏,遵循正常的屠宰场流程。与未致昏的禽类相比,致昏禽类的平均剪切值显著更低(6.0对7.1千克/克),尽管由训练有素的小组测量的嫩度评分没有显著差异(致昏禽类为6.6,未致昏禽类为6.1)。多汁性评分也没有显著差异(致昏禽类为5.5,未致昏禽类为5.8)。常规去骨禽类的平均剪切值(5.2千克/克)也显著低于热去骨禽类(7.9千克/克)。感官分析证实了剪切值结果。常规去骨鸡胸肉的平均嫩度评分为7.4,而热去骨鸡胸肉的平均嫩度评分为5.3。在多汁性方面未观察到统计学差异,尽管常规去骨鸡胸肉的评分为6.2,而热去骨鸡胸肉的评分为5.1。