Abstract

OBJECTIVES

The aim of the study was to evaluate the level of agreement between bitewing radiographs and oblique lateral radiographs for the diagnosis of dental caries extending into dentine, and to draw conclusions from the results as to which view is more useful.

SAMPLE

Radiographs were selected from patients attending an orthodontic assessment clinic: 53 patients, 52% male, 48% female, aged 6-18 years old. Total 105 bitewings and 105 oblique lateral radiographs.

METHODS

Contemporaneous bitewing and oblique radiographs taken over the period 1987-97 were independently assessed by two dentists for the presence of caries extending into dentine.

RESULTS

The agreement between the oblique lateral and the bitewing radiographs for the presence of approximal caries expressed in the form of Cohen's Kappa gave values of 0.64 for observer 1 and 0.53 for observer 2. For occlusal caries, values were 0.72 for observer 1 and 0.56 for observer 2. Kappa values for the level of agreement between observers and for the same observer on different occasions were within the range 0.5-0.95 for both types of film.

CONCLUSION

The Kappa values for the agreement between the two views as well as the intra- and inter-observer agreement and reproducibility of the oblique lateral view all fall in the range K = 0.5-0.75. Results suggested a fair to good agreement in diagnoses made using the two types of film. However, levels were lower than estimates of reproducibility reported for bitewing films alone.

摘要

目的

本研究旨在评估咬合翼片与斜侧位片在诊断累及牙本质的龋齿方面的一致性水平,并根据结果得出哪种视图更有用的结论。

样本

从参加正畸评估诊所的患者中选取X线片:53例患者,男性占52%,女性占48%,年龄在6至18岁之间。共有105张咬合翼片和105张斜侧位片。

方法

由两位牙医独立评估1987年至1997年期间同期拍摄的咬合翼片和斜位片,以确定是否存在累及牙本质的龋齿。

结果

以Cohen's Kappa形式表示的斜侧位片与咬合翼片在邻面龋存在情况上的一致性,观察者1的值为0.64,观察者2的值为0.53。对于咬合面龋,观察者1的值为0.72,观察者2的值为0.56。两种类型胶片在观察者之间以及同一观察者在不同情况下的一致性水平的Kappa值均在0.5至0.95范围内。

结论

两种视图之间的一致性Kappa值以及观察者内和观察者间的一致性以及斜侧位视图的可重复性均落在K = 0.5至0.75范围内。结果表明,使用这两种类型的胶片进行诊断时,一致性为中等至良好。然而,其水平低于仅针对咬合翼片报告的可重复性估计值。