Jackson-Pratt (JP) drains are commonly used after urologic surgery. One of the complications associated with the use of JP drains occurs when the drain breaks, leaving the distal fenestrated part at the time of attempted removal. We describe the endoscopic retrieval of a retained JP drain, which was safely performed with local anesthesia and minimal risk.
杰克逊-普拉特(JP)引流管常用于泌尿外科手术后。使用JP引流管的并发症之一是在试图拔除引流管时引流管断裂,导致远端带孔部分残留。我们描述了通过内镜取出残留的JP引流管的过程,该操作在局部麻醉下安全进行,风险极小。