The purpose of this study was to evaluate the ability of engine-driven nickel-titanium files to maintain the original curvature of root canals during canal preparation.
A total of 36 simulated curved canals on resin blocks were instrumented with Greater Taper (GT) files, ProFiles, and stainless steel files. With the mounting device, which can reproduce the same position of the resin blocks and the camera, the unprepared and prepared canals were accurately compared by means of a double-exposure photographic technique. The analysis of variance test was used for the statistical analysis of data obtained.
The canals prepared by means of a ProFile with a 6% taper up to the working length were excellent in taper and in maintaining the original curvature. The canals prepared with GT files were also found to be excellent in taper and in maintaining the original curvature; however, these canals showed a slight enlargement toward the inner side at the beginning of the curvature. The canals prepared with stainless steel files showed nontapered widening and severe transportation.
The canals prepared with GT files and ProFiles were excellently tapered and maintained the original curvature of the canals in comparison with the ones prepared with stainless steel files.
本研究的目的是评估发动机驱动的镍钛锉在根管预备过程中保持根管原始弯曲度的能力。
在树脂块上总共制作了36个模拟弯曲根管,分别用大锥度(GT)锉、ProFile锉和不锈钢锉进行预备。通过安装装置,该装置可以重现树脂块和相机的相同位置,利用双曝光摄影技术对未预备和已预备的根管进行精确比较。对获得的数据采用方差分析进行统计分析。
使用锥度为6%的ProFile锉预备至工作长度的根管在锥度和保持原始弯曲度方面表现出色。使用GT锉预备的根管在锥度和保持原始弯曲度方面也表现出色;然而,这些根管在弯曲起始处向内侧有轻微扩大。使用不锈钢锉预备的根管呈现非锥形增宽和严重的根管偏移。
与使用不锈钢锉预备的根管相比,使用GT锉和ProFile锉预备的根管具有良好的锥度,并保持了根管的原始弯曲度。