Suppr超能文献

The Alcon/Summit/Autonomous perspective on fixed vs. variable spot ablation.

作者信息

Pettit G H

机构信息

Alcon Summit Autonomous, Orlando, FL 32826, USA.

出版信息

J Refract Surg. 2001 Sep-Oct;17(5):S592-3. doi: 10.3928/1081-597X-20010901-17.

Abstract

The LADARVision system utilizes a small fixed diameter excimer laser beam coupled with a high fidelity eye tracking system to perform wavefront-guided refractive surgery. The fixed small beam provides a consistent ablation per pulse. By delivering many identical pulses in a predetermined pattern, which includes an optimized custom blend zone, the laser is able to ablate complex (higher order) corneal shapes accurately. The closed loop eye tracking system ensures that accurate ablation is delivered to the right place on the eye.

摘要

相似文献

1
The Alcon/Summit/Autonomous perspective on fixed vs. variable spot ablation.
J Refract Surg. 2001 Sep-Oct;17(5):S592-3. doi: 10.3928/1081-597X-20010901-17.
2
The VISX perspective on fixed vs. variable spot scanning ablation.
J Refract Surg. 2001 Sep-Oct;17(5):S594-5. doi: 10.3928/1081-597X-20010901-18.
3
How Alcon/Summit/Autonomous answers six important questions about their customized laser platform.
J Refract Surg. 2001 Sep-Oct;17(5):S613-7. doi: 10.3928/1081-597X-20010901-25.
4
Combining wavefront and topography data for excimer laser surgery: the future of customized ablation?
J Cataract Refract Surg. 2004 Feb;30(2):285-6. doi: 10.1016/j.jcrs.2004.01.013.
5
Customized corneal ablation.
Curr Opin Ophthalmol. 2002 Aug;13(4):256-60. doi: 10.1097/00055735-200208000-00013.
6
Highlights of the 1st International Congress of Wavefront Sensing and Aberration-free Refractive Correction.
J Refract Surg. 2001 Sep-Oct;17(5):S566-72. doi: 10.3928/1081-597X-20010901-12.
7
Future challenges to aberration-free ablative procedures.
J Refract Surg. 2000 Sep-Oct;16(5):S623-9. doi: 10.3928/1081-597X-20000901-28.
8
Lamellar or surface ablation?
J Cataract Refract Surg. 2003 May;29(5):858; author reply 858. doi: 10.1016/s0886-3350(03)00306-7.
9
Wave-front analysis: are we missing something?
Am J Ophthalmol. 2003 Aug;136(2):340-2. doi: 10.1016/s0002-9394(03)00272-1.
10
Combining wavefront and topography data.
J Cataract Refract Surg. 2005 Apr;31(4):646-7; author reply 647. doi: 10.1016/j.jcrs.2005.03.020.

引用本文的文献

1
Analytical optimization of the ablation efficiency at normal and non-normal incidence for generic super Gaussian beam profiles.
Biomed Opt Express. 2013 Jul 24;4(8):1422-33. doi: 10.1364/BOE.4.001422. eCollection 2013.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验