Madaric J, Mistrik A, Pacak J, Vrsansky M, Riecansky I
Department of Cardiology, Slovak Institute of Heart and Vascular Diseases, Bratislava, Slovakia.
Bratisl Lek Listy. 2001;102(9):400-5.
The aim of the study was the assessment of functional characteristics of the left internal mammary artery (LIMA) bypass in patients after coronary artery bypass grafting (CABG) in comparison with the native LIMA using colour-duplex ultrasound as the non-invasive diagnostic method.
We examined 303 patients after myocardial revascularization with the internal mammary artery bypass using the Hewllett Packard 2500, 5500 ultrasound units. Using the 7.5 MHz linear transducer we detected the LIMA from the left supraclavicular approach. We assessed the peak systolic velocity (PSV--cm/s), peak diastolic velocity (PDV--cm/s), end-diastolic velocity (EDV--cm/s) and we calculated the peak systolic/peak diastolic velocity ratio (SDVR) and resistance index RI (PSV-EDV/PSV). The obtained parameters were compared with the native LIMA flow characteristics of the 70 consecutive patients before CABG.
We observed the transformation of internal mammary artery flow from the predominantly systolic high resistance type of the native LIMA, to the low resistance biphasic waveform after its use as a coronary artery graft. We detected a significant increase of diastolic flow velocities and a significant decrease of resistance and of the SDVR ratio. In dysfunctional grafts we found a decrease of diastolic flow and an increase of LIMA resistance and SDVR.
The colour-duplex ultrasound is a perspective non-invasive method for the postoperative follow-up of patients with the LIMA graft. It allows the assessment of the bypass flow characteristics, functional status and patency and it could contribute to the early diagnosis of bypass failure. (Fig. 6, Tab. 4, Ref. 21.)
本研究旨在通过彩色双功超声这种非侵入性诊断方法,评估冠状动脉旁路移植术(CABG)后患者左乳内动脉(LIMA)旁路的功能特征,并与天然LIMA进行比较。
我们使用惠普2500、5500超声设备对303例接受乳内动脉旁路心肌血运重建的患者进行了检查。使用7.5MHz线性换能器从左锁骨上入路检测LIMA。我们评估了收缩期峰值流速(PSV,单位为cm/s)、舒张期峰值流速(PDV,单位为cm/s)、舒张末期流速(EDV,单位为cm/s),并计算了收缩期峰值/舒张期峰值流速比值(SDVR)和阻力指数RI(PSV-EDV/PSV)。将获得的参数与70例CABG术前患者的天然LIMA血流特征进行比较。
我们观察到乳内动脉血流从天然LIMA主要为收缩期高阻力型,转变为用作冠状动脉移植物后的低阻力双相波形。我们检测到舒张期流速显著增加,阻力和SDVR比值显著降低。在功能不良的移植物中,我们发现舒张期血流减少,LIMA阻力和SDVR增加。
彩色双功超声是一种用于LIMA移植物患者术后随访的有前景的非侵入性方法。它可以评估旁路血流特征、功能状态和通畅性,并有助于早期诊断旁路失败。(图6,表4,参考文献21)