To investigate the microleakage associated with a hybrid resin-based composite, Tetric Ceram, bonded with the single component dentin bonding agent Excite and Ariston pHc bonded with Ariston Liner. Ariston pHc bonded with Excite and Tetric Ceram bonded with Prime and Bond NT were used as controls.
Twenty-four extracted human premolars and molars were randomly assigned to four groups. Group 1: cavities were bonded with Excite and filled with Tetric Ceram. Group 2: cavities were bonded with Ariston Liner and filled with Ariston pHc. Group 3, control: cavities were bonded with Prime & Bond NT and filled with Tetric Ceram. Group 4, control: cavities were bonded Excite and filled with Ariston pHc. Cavities were cut in both the buccal and lingual surfaces. Half of each preparation was in enamel and the other was in cementum/dentin. The teeth were thermocycled at 15 degrees C for 2 s, 35 degrees C for 28 s and 45 degrees C for 2 s for 5,000 cycles after which the restorations were examined microscopically for leakage using procion brilliant red as a marker. SEM microphotographs were prepared from dye-labeled and non dye-labeled areas to illustrate the micromorphology of the systems.
None of the groups showed microleakage at the enamel margins. All groups showed microleakage at the gingival margins. At the gingival margin there was a significant difference between the groups (Kruskal-Wallis ANOVA, P= 0.1111.). Ariston pHc/Ariston Liner showed significantly lower microleakage scores than the other groups (Dunn's Multiple Comparison test). SEM showed that in non-dye labeled areas, Ariston pHc/Ariston Liner was in close apposition to the deeper dental tissues. The "total etch" technique resulted in a zone of demineralization. Debonding occurred at or near the top of the hybrid layer in >95% of specimens.
研究与混合型树脂基复合材料Tetric Ceram相关的微渗漏情况,该材料分别与单组分牙本质粘结剂Excite粘结以及与Ariston Liner粘结的Ariston pHc。将与Excite粘结的Ariston pHc以及与Prime and Bond NT粘结的Tetric Ceram用作对照。
将24颗拔除的人前磨牙和磨牙随机分为四组。第1组:窝洞用Excite粘结并用Tetric Ceram充填。第2组:窝洞用Ariston Liner粘结并用Ariston pHc充填。第3组,对照组:窝洞用Prime & Bond NT粘结并用Tetric Ceram充填。第4组,对照组:窝洞用Excite粘结并用Ariston pHc充填。在颊面和舌面均制备窝洞。每个窝洞的一半位于釉质内,另一半位于牙骨质/牙本质内。牙齿在15℃下保持2秒、35℃下保持28秒、45℃下保持2秒进行5000次热循环,之后使用普施安亮红作为标记对修复体进行显微镜下渗漏检查。从染色和未染色区域制备扫描电子显微镜照片以说明各系统的微观形态。
所有组在釉质边缘均未显示微渗漏。所有组在牙龈边缘均显示微渗漏。在牙龈边缘,各组之间存在显著差异(Kruskal-Wallis方差分析,P = 0.1111)。Ariston pHc/Ariston Liner显示出比其他组显著更低的微渗漏评分(邓恩多重比较检验)。扫描电子显微镜显示,在未染色区域,Ariston pHc/Ariston Liner与更深层的牙体组织紧密贴合。“全酸蚀”技术导致了脱矿区域。在超过95%的标本中,粘结失败发生在混合层顶部或其附近。