Felton Linda A, Garcia Daniel I, Farmer Ryan
University of New Mexico, College of Pharmacy, Albuquerque 87131, USA.
Drug Dev Ind Pharm. 2002 Apr;28(4):467-72. doi: 10.1081/ddc-120003008.
The objective of this study was to investigate the weight and weight uniformity of hard gelatin capsules filled with microcrystalline cellulose (MCC) and silicified microcrystalline cellulose (SMCC) powdered formulations. A tamping-type encapsulation apparatus was used to fill the capsules. The four formulations that were tested included MCC alone, MCC blended with fumed silica, SMCC, and high-density SMCC (SMCC-HD). The mean capsule weight and the average variation in mean capsule weight of each formulation were determined. Both SMCC products exhibited better flow than the MCC alone, with SMCC-HD being the freest flowing of the powders investigated. Capsules filled with the SMCC products had higher fill weights than those containing the MCC powders. The SMCC-containing capsules exhibited the lowest variation in weight, although these findings were not significantly different from either of the MCC-containing capsules. Significantly higher weight variations were found in capsules filled with SMCC-HD. A relationship between Carr's compressibility index and capsule weight variation was found, with more compressible materials producing more uniformly filled capsules. No relationship could be established between powder flow and capsule weight uniformity. These findings suggest that powder flow may not be a critical parameter in ensuring capsule weight uniformity when the encapsulation equipment utilizes a tamping-type filling system.
本研究的目的是调查填充微晶纤维素(MCC)和硅化微晶纤维素(SMCC)粉末制剂的硬明胶胶囊的重量及重量均匀性。采用捣实式包囊设备填充胶囊。所测试的四种制剂包括单独的MCC、与气相二氧化硅混合的MCC、SMCC和高密度SMCC(SMCC-HD)。测定了每种制剂的平均胶囊重量及平均胶囊重量的平均变化。两种SMCC产品的流动性均优于单独的MCC,其中SMCC-HD是所研究粉末中流动性最好的。填充SMCC产品的胶囊比含有MCC粉末的胶囊具有更高的装量。含SMCC的胶囊重量变化最小,尽管这些结果与任何一种含MCC的胶囊相比并无显著差异。发现填充SMCC-HD的胶囊重量变化显著更高。发现卡尔压缩指数与胶囊重量变化之间存在关系,即更易压缩的材料制成的胶囊装量更均匀。粉末流动性与胶囊重量均匀性之间未发现关系。这些发现表明,当包囊设备采用捣实式填充系统时,粉末流动性可能不是确保胶囊重量均匀性的关键参数。