Suppr超能文献

使用用于离子色谱的电解氢氧化钾发生器对碳酸盐洗脱液进行在线pH调节。

On-line pH modification of carbonate eluents using an electrolytic potassium hydroxide generator for ion chromatography.

作者信息

Novic Milko, Liu Yan, Avdalovic Nebojsa, Pihlar Boris

机构信息

National Institute of Chemistry, Ljubljana, Slovenia.

出版信息

J Chromatogr A. 2002 May 31;957(2):165-72. doi: 10.1016/s0021-9673(02)00349-7.

Abstract

Classical gradient elution, based on the application of a gradient pump used for mixing two or more prepared eluent components in pre-determined concentrations, was replaced by a chromatography system equipped with an isocratic pump and an electrolytic KOH generator. The isocratic pump delivered a constant concentration eluent composed of pure hydrogencarbonate solution. Carbonate ions, the main component of carbonate/hydrogencarbonate-based eluents, were formed by titration of hydrogencarbonate with KOH formed on-line in the electrolytic KOH generator. By changing the concentration of electrolytically-generated KOH, the eluent composition could be changed from pure hydrogencarbonate to a carbonate/hydrogencarbonate buffer, and finally to a carbonate/hydroxide-based eluent. The described system was tested to achieve pH-based changes of retention behavior of phosphate under constant inflow eluent composition conditions.

摘要

基于使用梯度泵将两种或更多种预先配制好的具有预定浓度的洗脱液组分进行混合的经典梯度洗脱,被配备等度泵和电解KOH发生器的色谱系统所取代。等度泵输送由纯碳酸氢盐溶液组成的恒定浓度洗脱液。碳酸根离子是基于碳酸盐/碳酸氢盐的洗脱液的主要成分,它是通过在电解KOH发生器中在线生成的KOH滴定碳酸氢盐而形成的。通过改变电解生成的KOH的浓度,洗脱液组成可以从纯碳酸氢盐变为碳酸盐/碳酸氢盐缓冲液,最终变为基于碳酸盐/氢氧化物的洗脱液。对所描述的系统进行了测试,以在恒定流入洗脱液组成条件下实现基于pH的磷酸盐保留行为变化。