Suppr超能文献

超声对带肌蒂骨移植在脊柱融合术中愈合的影响。

The effect of ultrasound on the healing of muscle-pediculated bone graft in spinal fusion.

作者信息

Aynaci Osman, Onder Cetin, Pişkin Ahmet, Ozoran Yavuz

机构信息

Department of Orthopaedic Surgery, Karadeniz Technical University, Trabzon, Turkey.

出版信息

Spine (Phila Pa 1976). 2002 Jul 15;27(14):1531-5. doi: 10.1097/00007632-200207150-00010.

Abstract

STUDY DESIGN

A rabbit model of posterolateral intertransverse process spine arthrodesis with and without the application of low-intensity ultrasound was used.

OBJECTIVE

To determine the effects of low-intensity ultrasound on the healing of muscle-pediculated bone graft.

SUMMARY OF BACKGROUND DATA

Earlier animal and clinical studies demonstrated the efficacy of low-intensity ultrasound stimulation in the acceleration of osteogenesis and fracture healing. This is the first study in which the beneficial effects of ultrasound on the healing of muscle-pediculated bone graft in spinal fusion have been assessed.

METHODS

In this study, 20 New Zealand rabbits were randomly assigned to two groups to undergo either spinal fusion using muscle-pedicle bone graft with ultrasound (ultrasound group) or muscle-pedicle bone graft without ultrasound (control group). Muscle-pediculated bone grafts were prepared from the posterosuperior iliac crest, erector spine muscle, and internal and external oblique muscle. This graft was placed bilaterally between the L5 and L6 transverse processes. Ultrasound was performed 20 minutes per day over the rabbits' lumbar spine. The rabbits were killed 6 weeks after surgery. The lumbar spines were evaluated radiologically, macroscopically, and histologically.

RESULTS

By macroscopic and radiologic findings, fusion was detected in 11 control group rabbits (55%) of the control group, and in 17 ultrasound group rabbits (85%). The fusion success rate for the rabbits treated with low-intensity ultrasound were statistically higher (P <0,05) than that for the control group. Histologic specimens showed increased bone formation in the fusions exposed to ultrasound. Mature fusions were present in rabbits that received ultrasound.

CONCLUSION

Low-intensity ultrasound in white rabbits increased the rate and quality of spinal fusion using muscle-pediculated bone grafts.

摘要

研究设计

采用了有或无低强度超声应用的兔后外侧横突间脊柱融合模型。

目的

确定低强度超声对带肌蒂骨移植愈合的影响。

背景资料总结

早期的动物和临床研究证明了低强度超声刺激在促进骨生成和骨折愈合方面的有效性。这是第一项评估超声对脊柱融合中带肌蒂骨移植愈合有益作用的研究。

方法

在本研究中,20只新西兰兔被随机分为两组,分别接受带超声的肌蒂骨移植脊柱融合术(超声组)或不带超声的肌蒂骨移植术(对照组)。带肌蒂骨移植取自髂后上棘、竖脊肌以及腹内斜肌和腹外斜肌。将该移植骨双侧置于L5和L6横突之间。每天对兔腰椎进行20分钟的超声处理。术后6周处死兔子。对腰椎进行放射学、大体和组织学评估。

结果

根据大体和放射学检查结果,对照组11只兔子(55%)检测到融合,超声组17只兔子(85%)检测到融合。接受低强度超声治疗的兔子的融合成功率在统计学上高于对照组(P<0.05)。组织学标本显示,接受超声处理的融合部位骨形成增加。接受超声治疗的兔子出现了成熟的融合。

结论

在白兔中,低强度超声提高了使用带肌蒂骨移植进行脊柱融合的速率和质量。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验