Tam K C, Lauritsch G, Sourbelle K
Siemens Corporate Research, Inc., Princeton, NJ, USA.
Phys Med Biol. 2002 Aug 7;47(15):2685-703. doi: 10.1088/0031-9155/47/15/310.
In backprojection cone-beam CT the cone-beam projection images are first filtered, then 3D backprojected into the object space. In this paper the point spread function (PSF) for the filtering operation is studied. For the cases where the normalization matrix is a constant, i.e. all integration planes intersect the scan path the same number of times, the derivation of the PSF is extended to the general case of limited angular range for the Radon line integrals. It is found that the 2D component of the PSF can be reduced to the form of space-variant 1D Hilbert transforms. The application of the PSF to a number of aspects in long object imaging will be discussed.
在反投影锥束CT中,锥束投影图像首先经过滤波,然后三维反投影到物体空间。本文研究了滤波操作的点扩散函数(PSF)。对于归一化矩阵为常数的情况,即所有积分平面与扫描路径相交的次数相同,将PSF的推导扩展到了拉东线积分有限角度范围的一般情况。结果发现,PSF的二维分量可以简化为空间可变一维希尔伯特变换的形式。将讨论PSF在长物体成像多个方面的应用。