实时质谱技术在环境有机地球化学中的应用。I. 计算机化高分辨率质谱法和气相色谱-低分辨率质谱法。

Application of real-time mass spectrometric techniques to environmental organic geochemistry. I. Computerized high resolution mass spectrometry and gas chromatography-low resolution mass spectrometry.

作者信息

Simoneit B R, Smith D H, Eglinton G

出版信息

Arch Environ Contam Toxicol. 1975;3(4):385-409. doi: 10.1007/BF02220811.

Abstract

LOGOS (Smith et al. 1971), an integrated mass spectrometer/computer system, has been employed in a series of experiments which illustrate the utility of the automated techniques of real-time mass spectrometry in the study of organic compounds in the environment. These techniques are shown to be particularly useful in resolving complex mixtures of organic compounds encountered in environmental studies. Complete high resolution mass spectrometry, particularly when used in conjunction with combined gas chromatography/mass spectrometry, and auxiliary techniques such as stable isotopic labeling are described to illustrate the type and scope of information that may be obtained. Illustrative samples include extracts of air- and waterborne particulates, extracts of water-soluble organic material, and a DDT metabolite from sewage sludge.

摘要

LOGOS(史密斯等人,1971年)是一种集成质谱仪/计算机系统,已被用于一系列实验中,这些实验展示了实时质谱自动化技术在环境中有机化合物研究中的实用性。结果表明,这些技术在解析环境研究中遇到的有机化合物复杂混合物方面特别有用。文中描述了完整的高分辨率质谱,特别是与气相色谱/质谱联用以及稳定同位素标记等辅助技术时,所获得信息的类型和范围。示例样本包括空气和水中颗粒物的提取物、水溶性有机物质的提取物以及污水污泥中的一种滴滴涕代谢物。