Goetz Wolfgang A, Lim Hou-Sen, Lansac Emmanuel, Weber Patricia A, Duran Carlos M G
The International Heart Institute of Montana Foundation at St Patrick Hospital and the University of Montana, Missoula 59802, USA.
J Heart Valve Dis. 2002 Sep;11(5):696-702.
A new bioprosthesis has been developed that is: (i) constructed from glutaraldehyde-treated autologous pericardium due to its lack of antigenicity and low cost; (ii) easily constructed in the operating room; (iii) stentless but easy to implant by using a temporary stent that is removed once its function is no longer necessary; and (iv) implanted with a single proximal suture and three commissural stitches.
This prosthesis was implanted in the subcoronary aortic position of six sheep. The mean prosthesis size was 19.7 +/- 3.5 mm, and manufacturing time 16 +/- 3 min. Cardiopulmonary bypass and cross-clamp times were 142.5 +/- 26.7 min and 100.2 +/- 28.8 min, respectively. Three sheep were euthanized at three, seven, or 27 days, and the remainder at five months postoperatively.
In all cases the valve was competent and the single commissural stitches were well-anchored. The pericardium was pliable in all cases, but one animal had obvious endocarditis (at 27 days). Small calcific nodules were found at the commissures in valves explanted at five months. Histology showed an intact collagen and elastin structure, and neointimal growth was seen covering the basal quarter of the leaflets and commissures.
This new bioprosthesis might offer a particularly attractive alternative for the young patient population of the developing world. The simplicity of construction, low cost, and absence of any need for anticoagulation makes this prosthesis close to the ideal aortic valve substitute.
已研发出一种新型生物假体,其具有以下特点:(i)由经戊二醛处理的自体心包构建而成,因其无抗原性且成本低;(ii)易于在手术室构建;(iii)无支架,但使用临时支架易于植入,一旦其功能不再需要即可移除;(iv)通过单个近端缝线和三个瓣叶交界缝线植入。
将该假体植入六只绵羊的冠状动脉下主动脉位置。假体平均尺寸为19.7±3.5毫米,制造时间为16±3分钟。体外循环和主动脉阻断时间分别为142.5±26.7分钟和100.2±28.8分钟。三只绵羊在术后3天、7天或27天实施安乐死,其余在术后五个月实施安乐死。
在所有病例中,瓣膜功能良好,单个瓣叶交界缝线固定良好。所有病例中心包均柔韧,但有一只动物出现明显的心内膜炎(在27天时)。在五个月时取出的瓣膜瓣叶交界处发现小的钙化结节。组织学显示胶原和弹性蛋白结构完整,可见新生内膜生长覆盖瓣叶和瓣叶交界处的基底部四分之一。
这种新型生物假体可能为发展中世界的年轻患者群体提供一种特别有吸引力的替代方案。其构建简单、成本低且无需抗凝,使得该假体接近理想的主动脉瓣替代品。