To assess the effect of an insole with subtalar strapping on patients with medial compartment osteoarthritis (OA) of the knee.
Novel lateral wedged insoles with elastic subtalar strapping (the subtalar strapping support group) and ankle supporters with a lateral wedged heel insert (the sock-type ankle support group) were prepared. Eighty-eight female outpatients with knee OA were treated with 1 of the 2 insoles for 8 weeks. Femorotibial angle was assessed by standing radiographs with and without unilateral insole use for each subject. Symptoms of knee OA were evaluated according to the severity index of Lequesne et al at baseline and at the final assessment.
Participants wearing the insole with subtalar strapping (n = 42) demonstrated significantly decreased femorotibial angle (an average of change: -3.1 degrees +/- 2.5 degrees, P < 0.0001), but a significant difference was not found in the sock-type ankle support group (n = 46; -0.4 degrees +/- 1.1 degrees, P > 0.05). In the subtalar strapping support group, pain during bed rest with full extension of the knee (P < 0.0001), pain after getting up (P = 0.04), pain on getting up from a seated position (P = 0.021), maximum distance walked (P = 0.009), and aggregate severity score (P < 0.0001) were significantly improved compared with baseline. In contrast, significant symptomatic improvement was detected only in the aggregate score (P = 0.016) in the sock-type ankle support group, but not in any of the 10 specific categories.
The lateral wedged insole with subtalar strapping induces correction of the femorotibial angle and symptomatic relief in patients with varus-deformity knee OA.
评估带有距下绑扎带的鞋垫对膝关节内侧间室骨关节炎(OA)患者的影响。
制备了带有弹性距下绑扎带的新型外侧楔形鞋垫(距下绑扎带支撑组)和带有外侧楔形足跟垫的脚踝支撑器(袜子型脚踝支撑组)。88名膝关节OA女性门诊患者使用这两种鞋垫中的一种进行为期8周的治疗。通过站立位X线片评估每位受试者在使用和不使用单侧鞋垫时的股胫角。根据Lequesne等人的严重程度指数在基线和最终评估时评估膝关节OA的症状。
佩戴带有距下绑扎带鞋垫的参与者(n = 42)股胫角显著减小(平均变化:-3.1度±2.5度,P < 0.0001),但在袜子型脚踝支撑组(n = 46;-0.4度±1.1度,P > 0.05)中未发现显著差异。在距下绑扎带支撑组中,膝关节完全伸直卧床休息时的疼痛(P < 0.0001)、起床后的疼痛(P = 0.04)、从坐位起身时的疼痛(P = 0.021)、最大行走距离(P = 0.009)和综合严重程度评分(P < 0.0001)与基线相比均有显著改善。相比之下,袜子型脚踝支撑组仅在综合评分(P = 0.016)上有显著的症状改善,在10个具体类别中均未出现改善。
带有距下绑扎带的外侧楔形鞋垫可使膝内翻畸形骨关节炎患者的股胫角得到矫正并缓解症状。