Dybczyński R
Department of Analytical Chemistry, Institute of Nuclear Chemistry and Technology (INCT), 03-195 Warszawa, Dorodna 16, Poland.
Food Addit Contam. 2002 Oct;19(10):928-38. doi: 10.1080/0265203021000011791.
A general preparation and certification scheme used in the Institute of Nuclear Chemistry and Technology (INCT) for the preparation and use of certified reference materials (CRMs) for inorganic trace analysis is presented and contrasted with approaches used by other CRM producers. 'Definitive' and 'very accurate' methods have a role, based on a combination of neutron activation and quantitative and selective post-irradiation isolation of an indicator radionuclide by column chromatography. Natural matrix CRMs of biological origin including the typical food products are reviewed and the need is identified for new well-characterized materials that would also be suitable for micro-analytical techniques such as PIXE, EDXRF, SS-AAS, etc. There are various approaches to studying homogeneity and its relationship with particle size distribution of a material, and the many problems associated with reliable particle size measurements of CRMs by various techniques are illustrated using real examples. There is an equation relating Ingamells' sampling constant to the mass of single particle of a powder material and this theoretical approach has been compared with experimental results obtained for some CRMs.
介绍了核化学与技术研究所(INCT)用于制备和使用无机痕量分析认证参考物质(CRM)的通用制备和认证方案,并与其他CRM生产商使用的方法进行了对比。基于中子活化以及通过柱色谱对指示放射性核素进行定量和选择性辐照后分离的组合,“权威”和“非常准确”的方法发挥了作用。对包括典型食品在内的生物源天然基质CRM进行了综述,并确定了对新型特征明确的材料的需求,这些材料也适用于PIXE、EDXRF、SS-AAS等微分析技术。研究材料均匀性及其与粒度分布关系有多种方法,通过实际例子说明了使用各种技术对CRM进行可靠粒度测量所涉及的诸多问题。有一个将英格梅尔斯采样常数与粉末材料单颗粒质量相关联的方程,并且已将这种理论方法与一些CRM获得的实验结果进行了比较。