Saraçoğlu Ahmet, Ozpinar Birgül
Faculty of Dentistry, Ege University, Protetik Diş Tedavisi Anabilim Dali, 35100 Bornova, Izmir, Turkey.
J Prosthet Dent. 2002 Nov;88(5):522-6. doi: 10.1067/mpr.2002.129064.
Indicators used to locate and eliminate occlusal disharmonies have not demonstrated specific sensitivity and reliability.
The sensitivity and reliability of articulating papers, foils, silk strips, and T-Scan systems used as occlusal indicators were investigated. The effect of saliva on the materials also was determined.
In the in vitro part of the study, a test model (mounted in an articulator and in a universal testing machine) was established with the use of maxillary and mandibular dentate casts. Articulating papers, foils, silk strips, and the T-Scan system were used to examine the loss of sensitivity of the recording materials after 3 consecutive strokes. The differences in the contact points of the test model determined by each of the recording materials were evaluated both in the articulator and in a universal testing machine. In the in vivo part of the study, occlusal contact recordings of 3 subjects were made before and after drying their mouths. The significance of the differences between the strokes repeated more than once was evaluated with the Friedman 2-way analysis of variance and Kruskal-Wallis tests. To examine the effect of the oral environment, the Wilcoxon matched-pairs signed-ranks test was applied. In all statistical analyses, the level of significance was alpha=.05.
The results demonstrated significant differences in the sensitivity of the recording materials tested (P<.001). The sensitivity of all recording materials decreased after multiple use (P<.001), and the loss of recording accuracy was significant (P<.001). All recording materials except the T-Scan were affected by the presence of saliva (P<.01).
Within the limitations of this study, the results indicated that multiple use of the recording materials tested may lead to inaccurate occlusal analysis results. It is recommended that the recording materials be used only once and that the teeth be dry during occlusal analysis.
用于定位和消除咬合不协调的指标尚未显示出特定的敏感性和可靠性。
研究用作咬合指标的咬合纸、箔片、丝绸条和T-Scan系统的敏感性和可靠性。还确定了唾液对这些材料的影响。
在该研究的体外部分,使用上颌和下颌有牙模型建立了一个测试模型(安装在咬合架和万能试验机中)。使用咬合纸、箔片、丝绸条和T-Scan系统检查记录材料在连续3次咬合后敏感性的丧失情况。在咬合架和万能试验机中评估每种记录材料所确定的测试模型接触点的差异。在该研究的体内部分,对3名受试者在擦干口腔前后进行咬合接触记录。使用Friedman双向方差分析和Kruskal-Wallis检验评估多次重复咬合之间差异的显著性。为了检查口腔环境的影响,应用了Wilcoxon配对符号秩检验。在所有统计分析中,显著性水平为α = 0.05。
结果表明,所测试的记录材料的敏感性存在显著差异(P < 0.001)。多次使用后,所有记录材料的敏感性均下降(P < 0.001),记录准确性的丧失显著(P < 0.001)。除T-Scan外,所有记录材料都受到唾液存在的影响(P < 0.01)。
在本研究的局限性范围内,结果表明所测试的记录材料多次使用可能导致不准确的咬合分析结果。建议记录材料仅使用一次,并且在咬合分析期间牙齿保持干燥。