Lewis John G, Lewis Mark G, Elder Peter A
Steroid and Immunobiochemistry Laboratory, Canterbury Health Laboratories, PO Box 151, Christchurch, New Zealand.
Clin Chim Acta. 2003 Feb;328(1-2):121-8. doi: 10.1016/s0009-8981(02)00417-5.
Adrenal function is commonly assessed by measuring plasma cortisol following synthetic ACTH (synacthen) challenge. Generally little regard is given to plasma levels of corticosteroid-binding globulin (CBG). We have developed and validated an enzyme-linked immunosorbent assay (ELISA) for CBG and together with plasma cortisol calculated the "free cortisol index" as an additional parameter for assessing adrenal function.
A monoclonal antibody was raised against CBG. The antibody was characterized by Western blotting and used with a polyclonal antibody to develop a direct ELISA for CBG. Together with total plasma cortisol, the free cortisol index was derived and correlated with an "in-house" ligand binding method for assessing free cortisol. The free cortisol index was also used as an adduct to total plasma cortisol in assessing adrenal function.
The ELISA has acceptable performance and the free cortisol index correlates well with free cortisol determined by ligand binding. In addition, we show that CBG levels following synthetic ACTH (synacthen) show a modest but significant decline.
We conclude that the measurement of both plasma CBG and total cortisol to derive the free cortisol index may provide an additional parameter in the interpretation of the short synacthen test and that there is a decline in plasma CBG over this test.
肾上腺功能通常通过在合成促肾上腺皮质激素(赛增)刺激后测量血浆皮质醇来评估。一般很少关注皮质类固醇结合球蛋白(CBG)的血浆水平。我们开发并验证了一种用于CBG的酶联免疫吸附测定(ELISA),并结合血浆皮质醇计算“游离皮质醇指数”,作为评估肾上腺功能的一个额外参数。
制备了一种针对CBG的单克隆抗体。通过蛋白质印迹法对该抗体进行了表征,并与一种多克隆抗体一起用于开发一种针对CBG的直接ELISA。结合总血浆皮质醇,得出游离皮质醇指数,并将其与一种用于评估游离皮质醇的“内部”配体结合方法进行相关性分析。游离皮质醇指数还被用作总血浆皮质醇的附加物来评估肾上腺功能。
该ELISA具有可接受的性能,游离皮质醇指数与通过配体结合测定的游离皮质醇相关性良好。此外,我们发现合成促肾上腺皮质激素(赛增)刺激后CBG水平有适度但显著的下降。
我们得出结论,测量血浆CBG和总皮质醇以得出游离皮质醇指数,可能为短期赛增试验的解读提供一个额外参数,并且在该试验过程中血浆CBG会下降。