The accuracy of surgical drilling guides was assessed for placement of zygoma implants. Six zygoma fixtures of length 45 mm (Nobel Biocare, Göteborg, Sweden) were placed in three formalin-fixed human cadavers using surgical drilling guides. The fabrication of these custom-made drilling guides was based on three-dimensional computerized tomography (3D-CT) data for the maxillary-zygomatic complex. The installation of the implants was simulated preoperatively using an adopted 3D-CT planning system. In addition, anatomical measurements of the zygomatic bone were performed on the 3D images. The preoperative CT images were then matched with postoperative ones in order to assess the deviation between the planned and installed implants. The angle between the planned and actually placed implants was < 3 degrees in four out of six cases. The largest deviation found at the exit point of one of the six implants was 2.7 mm. The present study showed that the use of surgical drilling guides should be encouraged for zygoma implant placement because of the lengths of the implants involved and the anatomical intricacies of the region.
评估了用于颧骨种植体植入的手术钻孔导板的准确性。使用手术钻孔导板,将6枚长度为45毫米的颧骨固定装置(诺贝尔生物科技公司,瑞典哥德堡)植入3具经福尔马林固定的人类尸体中。这些定制钻孔导板的制作基于上颌-颧骨复合体的三维计算机断层扫描(3D-CT)数据。术前使用改良的3D-CT规划系统模拟种植体的植入。此外,在3D图像上对颧骨进行了解剖学测量。然后将术前CT图像与术后图像进行匹配,以评估计划植入与实际植入种植体之间的偏差。6例中有4例计划植入与实际植入种植体之间的角度小于3度。6枚种植体中1枚在出口点的最大偏差为2.7毫米。本研究表明,由于所涉及的种植体长度以及该区域解剖结构的复杂性,在颧骨种植体植入时应鼓励使用手术钻孔导板。