García M D, Cacicedo L, de Escobar G
Rev Esp Fisiol. 1976 Mar;32(1):59-75.
A heterologous RIA system is described for the determination of TSH in rat plasma. The antibody was obtained by us in guinea-pigs and directed against bovine-TSH (B-TSH). It was chosen from several antisera as the one showing the greatest potency in vivo against rat TSH, using the McKenzie bioassay. Two different antigens were tried for radioiodination: B-TSH (B-TSH) and a purified mouse tumour TSH (M-TSH). The choice of labeled antigen proved to be critical. It was not possible to develop a reliable RIA with B-TSH. Using M-TSH, however, a RIA was developed which is sensitive enough to detect differences between normal and lower than normal plasma TSH levels. The reproducibility, sensitivity and specificity of the RIA are described, as well as several procedures which shorten the time spent on a given assay, and at the same time decrease inter and intra-assay variations. Some of the results obtained with experimental plasmas were compared to the in vivo potency of the samples in the McKenzie bioassay. The results obtained with the present RIA have also been validated physiologically by carrying out the determinations on plasmas obtained from rats submitted to situations known to decrease (hypophysectomy, treatment with thyroid hormones, ether anaesthesia) or increase (injection of TRH, thyroidectomy, treatment with goitrogens) circulating TSH levels. The circulating TSH levels of normal rats found with the present RIA compare well with values obtained with the homologous immunoreactants available from NIAMDD at NIH (U.S.A.).
本文描述了一种用于测定大鼠血浆中促甲状腺激素(TSH)的异源放射免疫分析(RIA)系统。我们在豚鼠体内获得了针对牛促甲状腺激素(B-TSH)的抗体。通过麦肯齐生物测定法,从几种抗血清中挑选出该抗体,它在体内对大鼠TSH显示出最强的效力。尝试了两种不同的抗原进行放射性碘化:B-TSH和纯化的小鼠肿瘤TSH(M-TSH)。结果证明标记抗原的选择至关重要。使用B-TSH无法开发出可靠的RIA。然而,使用M-TSH开发出了一种RIA,其灵敏度足以检测正常血浆TSH水平与低于正常水平之间的差异。描述了该RIA的重复性、灵敏度和特异性,以及几种缩短单次测定时间并同时减少测定间和测定内变异的方法。将实验血浆获得的一些结果与麦肯齐生物测定法中样品的体内效力进行了比较。通过对已知会降低(垂体切除、甲状腺激素治疗、乙醚麻醉)或升高(注射促甲状腺激素释放激素、甲状腺切除、致甲状腺肿物质治疗)循环TSH水平的大鼠血浆进行测定,从生理学角度验证了本RIA获得的结果。用本RIA测定的正常大鼠循环TSH水平与美国国立卫生研究院(NIH)国家糖尿病、消化和肾脏疾病研究所(NIAMDD)提供的同源免疫反应物获得的值相当。