Arakawa H, Shiokawa M, Imamura O, Maeda M
School of Pharmaceutical Sciences, Showa University, Shinagawa-ku, Tokyo 142-8555, Japan.
Anal Biochem. 2003 Mar 15;314(2):206-11. doi: 10.1016/s0003-2697(02)00657-7.
This paper describes a novel bioluminescent assay of alkaline phosphatase (ALP) utilizing ATP-sulfurylase and the luciferin-luciferase reaction. The principle governing the assay is as follows. Adenosine-3'-phosphate-5'-phosphosulfate, which serves as the substrate for ALP, is hydrolyzed enzymatically to produce adenosine-5'-phosphosulfate (APS). APS is converted into ATP by ATP-sulfurylase in the presence of pyrophosphate. The ATP produced is detected by the luciferin-luciferase reaction. The measurable range was 1 zmol to 100 fmol/assay and the detection limit at blank+3 SD was 10 zmol/assay. The coefficient of variation (CV, n=5) was examined at each point of the standard curve; the mean CV percentage was 4.47% (n=6). This assay system was applied to enzyme immunoassay of human chorionic gonadotropin and allele-specific PCR enzyme-linked immunosorbent assay of verotoxin gene using ALP as the label enzyme; 10(-2) mIU/mL hCG in urine and 5 pg of Escherichia coli O157 DNA could be assayed directly and with high sensitivity by the proposed method.