Abstract

INTRODUCTION

Drug-induced QT prolongation is a major clinical risk factor for arrhythmia induction, particularly torsades de pointes. QT interval is rate dependent, and many formulae exist that attempt to correct QT for changes in heart rate. Most correction factors are acknowledged to overcorrect at high heart rates, undercorrect at low heart rates, and tend to be species specific. Data collected from computerised data acquisition systems are normally reported as means over a given logging period, and so extremes of heart rate are averaged out. Therefore, the aim of this study was to develop a technique for assessing drug-induced changes in the QT/RR relationship, which is simple, suitable for small group sizes, and better able to determine rate-dependent effects of drugs.

METHODS

Telemetred beagle dogs (n=4) instrumented for the measurement of electrocardiogram (ECG) were monitored for four separate 20-h periods to define the control QT/RR relationship. Data were binned by RR interval, in 10 ms bins, to produce a control curve. Each dog was treated with vehicle and sotalol (4, 8, 32 mg/kg) in a crossover design to determine whether drug-induced changes in the QT/RR relationship could be detected using the data binning technique.

RESULTS

The control QT/RR relationship was curvilinear with a steep section for RR intervals below 580 ms, and was much less steep after this point. Sotalol produced QT prolongation and bradycardia-Fridericia's correction (QTf) reduced the magnitude of this prolongation. The data analysed by the binning technique showed a larger prolongation in QT than was suggested by QTf, and an inverse frequency-dependent response.

DISCUSSION

Beat-to-beat analysis and binning allows accurate determination of the QT/RR relationship and assessment of QT prolongation without recourse to mathematical modelling. It also highlights the importance of assessing QT effects in well-trained animals over a range of heart rates.

摘要

引言

药物诱导的QT间期延长是诱发心律失常的主要临床危险因素,尤其是尖端扭转型室性心动过速。QT间期受心率影响,存在多种公式试图根据心率变化校正QT间期。大多数校正因子在高心率时校正过度,在低心率时校正不足,且往往具有物种特异性。从计算机数据采集系统收集的数据通常报告为给定记录期内的平均值,因此心率极值被平均化了。因此,本研究的目的是开发一种评估药物诱导的QT/RR关系变化的技术,该技术简单,适用于小样本量,并且能够更好地确定药物的心率依赖性效应。

方法

对4只植入心电图(ECG)测量仪器的遥测比格犬进行4个独立的20小时监测期,以确定对照QT/RR关系。数据按RR间期以10毫秒的间隔进行分组,以生成对照曲线。每只犬采用交叉设计,分别给予溶媒和索他洛尔(4、8、32mg/kg),以确定是否可以使用数据分组技术检测到药物诱导的QT/RR关系变化。

结果

对照QT/RR关系呈曲线,RR间期低于580毫秒时斜率较陡,此后斜率明显变缓。索他洛尔导致QT间期延长,采用弗里德里西亚校正法(QTf)可降低这种延长的幅度。通过分组技术分析的数据显示,QT间期延长幅度大于QTf所提示的幅度,且呈现频率依赖性反向反应。

讨论

逐搏分析和分组可准确确定QT/RR关系,并评估QT间期延长,而无需借助数学建模。这也凸显了在一系列心率范围内对训练良好的动物评估QT效应的重要性。