Tibial fixation of hamstring tendon grafts has been the weak link in anterior cruciate ligament reconstruction.
Use of a central four-quadrant sleeve and screw provides superior fixation when compared with standard interference screw fixation.
Controlled laboratory study.
In eight pairs of cadaveric knees each anterior cruciate ligament was reconstructed using either an interference screw or a central sleeve and screw on the tibial side. The specimens were then subjected to cyclic loading followed by a load-to-failure test.
The load required to cause 1 and 2 mm of graft laxity, defined as the separation of the femur and the tibia at the points of graft fixation, was significantly greater with the sleeve and screw than with the interference screw (at 2 mm: sleeve and screw, 216.1 +/- 30.1 N; interference screw, 167.0 +/- 33.2 N). The force at initial slippage for each of the graft strands was significantly higher with use of the central sleeve and screw.
The four-quadrant sleeve and screw device may provide greater surface area for healing of hamstring tendon grafts and allow equal tensioning of graft strands before fixation. These factors are associated with increased strength of fixation and reduced laxity of the graft after cyclic loading.
Use of the central four-quadrant sleeve and screw system offers increased strength of fixation in anterior cruciate ligament reconstruction with hamstring tendon graft.
腘绳肌腱移植的胫骨固定一直是前交叉韧带重建中的薄弱环节。
与标准的干涉螺钉固定相比,使用中央四象限套筒和螺钉可提供更好的固定效果。
对照实验室研究。
在八对尸体膝关节中,每侧前交叉韧带均采用干涉螺钉或中央套筒和螺钉进行胫骨侧重建。然后对标本进行循环加载,随后进行破坏载荷试验。
导致移植肌腱松弛1毫米和2毫米(定义为在移植肌腱固定点处股骨与胫骨的分离)所需的载荷,使用套筒和螺钉时显著高于干涉螺钉(在2毫米时:套筒和螺钉,216.1±30.1牛;干涉螺钉,167.0±33.2牛)。使用中央套筒和螺钉时,每条移植肌腱束初始滑动时的力显著更高。
四象限套筒和螺钉装置可为腘绳肌腱移植的愈合提供更大的表面积,并在固定前使移植肌腱束均匀张紧。这些因素与固定强度增加和循环加载后移植肌腱的松弛减少有关。
在腘绳肌腱移植重建前交叉韧带时,使用中央四象限套筒和螺钉系统可提高固定强度。