Suppr超能文献

开发一种用于检测早期HIV-1感染的新型低灵敏度酶免疫测定法。

Development of a new less-sensitive enzyme immunoassay for detection of early HIV-1 infection.

作者信息

Rawal Bhupat D, Degula Azucena, Lebedeva Ludmila, Janssen Robert S, Hecht Frederick M, Sheppard Haynes W, Busch Michael P

机构信息

Blood Centers of the Pacific, San Francisco, California 94118, USA.

出版信息

J Acquir Immune Defic Syndr. 2003 Jul 1;33(3):349-55. doi: 10.1097/00126334-200307010-00009.

Abstract

The sensitive/less-sensitive (S/LS) enzyme immunoassay (EIA) testing strategy for discriminating "early" from "longstanding" HIV infection has been widely applied for detecting recent seroconverters and estimating HIV incidence rates. The originally developed assay (3A11-LS EIA; Abbott Laboratories, Abbott Park, IL) involved performance of LS EIAs using a bead-based assay that required specialized equipment and reagents of limited availability. In contrast, 96-microwell-based EIAs are more universally applied for HIV serodiagnosis throughout the world. The authors report development and preliminary validation of an LS protocol using an EIA in a 96-well format: the Vironostika HIV-1 MicroElisa System (Vironostika-LS EIA; Bio Merieux, Raleigh, NC). The results with samples from recent HIV-1 seroconverters, persons with longstanding HIV-1 asymptomatic infection, patients on highly active antiretroviral therapy, and AIDS patients show a high degree of correlation between the Vironostika-LS EIA and 3A11-LS EIA. The authors also demonstrate that the Abbott 3A11-LS EIA and Vironostika-LS EIA performed comparably on HIV-1-positive samples from persons infected with non-B HIV-1 subtypes. These results support the potential use of the Vironostika-LS EIA for detection of recent HIV-1 infections for incidence projections and for other epidemiologic, clinical, and molecular surveillance applications.

摘要

用于区分“早期”与“长期存在”HIV感染的灵敏/低灵敏(S/LS)酶免疫测定(EIA)检测策略已广泛应用于检测近期血清转化者和估计HIV发病率。最初开发的检测方法(3A11-LS EIA;雅培实验室,伊利诺伊州雅培公园)涉及使用基于磁珠的检测方法进行低灵敏EIA检测,该方法需要专门设备且试剂可用性有限。相比之下,基于96孔板的EIA在全球范围内更普遍地应用于HIV血清学诊断。作者报告了一种使用96孔板EIA的低灵敏方案的开发和初步验证:Vironostika HIV-1 MicroElisa系统(Vironostika-LS EIA;生物梅里埃公司,北卡罗来纳州罗利)。来自近期HIV-1血清转化者、长期HIV-1无症状感染者、接受高效抗逆转录病毒治疗的患者以及艾滋病患者的样本检测结果显示,Vironostika-LS EIA与3A11-LS EIA之间具有高度相关性。作者还证明,雅培3A11-LS EIA和Vironostika-LS EIA对感染非B型HIV-1亚型者的HIV-1阳性样本检测表现相当。这些结果支持Vironostika-LS EIA在检测近期HIV-1感染以进行发病率预测以及其他流行病学、临床和分子监测应用方面的潜在用途。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验