Zhang Quan-mei, Ge Ji-hong, Mai Er-dan, Su Qi-zhi, Chen Jian
First Affiliated Hospital, Xinjiang Medical University, Urumqi 830054, China.
Yao Xue Xue Bao. 2003 Apr;38(4):294-7.
To study the dissolution rate of solid pharmaceutical preparation on-line, a multiple channel fiber-optic chemical sensor based on fluorescence multiple quenching (FOCSMQ) without filtering and sampling was made.
Using the multiple channel FOCSMQ linked with computer, the dissolution rates of ofloxacin tablets, metronidazole tablets and nitrofurantoin tablets were monitored continuously on-line. The instrument can give the sample data, display the real time curve and calculate the T1/2 and td automatically. A computer was used to select the best function from five common fitting models to fit the dissolution curve.
The average recoveries of the FOCSMQ method were 97.4%-104.4%, 97.4%-103.8% and 96.6%-102.1%. The RSDs (n = 6) of within-day and between-day were less than 5%. The parameters of the dissolution and all results of measurement using the instrument have no significant difference compared with the Chinese Pharmacopoeia (ChP) (2000) method and the United States Pharmacopoeia (USP) (23) method (P > 0.05). It does not need sampling and dilution, and never contaminate sample. It can shorten time of the experiment.
The method is simple, rapid and reliable.
为在线研究固体药物制剂的溶出速率,制备了一种基于荧光多重猝灭的多通道光纤化学传感器(FOCSMQ),无需过滤和采样。
使用与计算机相连的多通道FOCSMQ,在线连续监测氧氟沙星片、甲硝唑片和呋喃妥因片的溶出速率。该仪器能给出样品数据,显示实时曲线,并自动计算T1/2和td。利用计算机从五种常用拟合模型中选择最佳函数来拟合溶出曲线。
FOCSMQ法的平均回收率分别为97.4%-104.4%、97.4%-103.8%和96.6%-102.1%。日内和日间的相对标准偏差(n = 6)均小于5%。与《中国药典》(2000年版)方法和《美国药典》(第23版)方法相比,该仪器的溶出参数及所有测量结果均无显著差异(P > 0.05)。它无需采样和稀释,且不会污染样品。可缩短实验时间。
该方法简便、快速、可靠。