[使用Amplatzer装置经皮闭合继发孔房间隔缺损。关于突尼斯最初5例病例]

[Percutaneous closure of interatrial ostium secundum defects using the Amplatzer device. Apropos of the initial 5 Tunisian cases].

作者信息

Mechmèche Rachid, Boussaâda Rafik, Farhati Ali, Ben Fredj Sahbi, Petit Jérôme

机构信息

Service des Explorations Fonctionnelles Cardiologiques, Hôpital la Rabta, Tunis.

出版信息

Tunis Med. 2003 May;81(5):339-44.

Abstract

We report our initial experience with percutaneous closure of ostium secundum atrial septal defect using Amplatzer device. Between september 2000 and July 2001, five devices were implanted in 5 patients, 4 female and 1 male. Age ranged from 18 to 66 years. A large atrial septal defect with significant shunting was diagnosed by trans thoracic echocardiography. Procedures were performed under general anesthesia with trans esophageal echocardiography guidance. Stretched diameter of atrial septal defects was determined by balloon sizing, ranged from 21 to 32 mm. Amplatzer devices of 20 to 32 mm were respectively deployed. No complications occurred during the procedure. Total occlusion of interatrial communication, was observed in one patient, immediately after the procedure, and in 3 patients 24 hours later. First 3 patients were controlled at months follow up were free of complications. Closure of atrial septal defect with Amplatzer device appears feasible and safe. However, long term results in comparison to surgery remain to be determined before definite conclusion regarding its use can be made.

摘要

我们报告了使用Amplatzer封堵器经皮闭合继发孔型房间隔缺损的初步经验。在2000年9月至2001年7月期间,5例患者植入了5个封堵器,其中4例女性,1例男性。年龄在18至66岁之间。经胸超声心动图诊断为大型房间隔缺损且有明显分流。手术在全身麻醉和经食管超声心动图引导下进行。通过球囊测量确定房间隔缺损的伸展直径,范围为21至32毫米。分别部署了20至32毫米的Amplatzer封堵器。手术过程中未发生并发症。1例患者在手术后立即观察到心房交通完全闭塞,3例患者在24小时后闭塞。前3例患者在随访数月时未出现并发症。使用Amplatzer封堵器闭合房间隔缺损似乎是可行和安全的。然而,与手术相比,其长期结果在就其使用得出明确结论之前仍有待确定。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验