作为恶性高热诊断技术的自旋标记红细胞的电子顺磁共振研究。

An EPR investigation of spin-labelled erythrocytes as a diagnostic technique for malignant hyperthermia.

作者信息

Cooper P, Kudynska J, Buckmaster H A, Kudynski R

机构信息

Department of Anaesthesia, Faculty of Medicine, University of Calgary, Canada.

出版信息

Biochim Biophys Acta. 1992 Jun 9;1139(1-2):70-6. doi: 10.1016/0925-4439(92)90084-z.

Abstract

Spin labelled (7-, 12- and 16- doxylsteric (DS) acid) erythrocyte (red blood cell) membranes isolated from six malignant hyperthermia susceptible (MHS) and six malignant hyperthermia normal (MHN) volunteer donors were characterized using the order parameter (S) and rotational correlation time (tau r) determined from 37 degrees C, 9 GHz electron paramagnetic resonance spectra. These parameters were found to decrease due to the increasing fluidization of the membrane as the halothane and benzyl alcohol sample concentration is increased and that significant differences exist in the values of S and tau r between the MHS and MHN sample groups, but that the differences in these parameters between the presence and absence of an external fluidizing agent are not significant for both sample groups. In the absence of these fluidizing agents, the mean values and standard errors of S at 37 degrees C for MHS and MHN are 0.643(2) and 0.652(3) for 7-DS, 0.554(2) and 0.563(3) for 12-DS, respectively, and of tau r are 2.139(12) and 2.223(13) ns for 16-DS, respectively. The values of S and tau r are significantly smaller for the MHS group than for the MHN group contrary to some previous reports. These observations revise and extend previous reports and show that the observed values of S and tau r in the absence of a fluidizing agent depend on the erythrocyte membrane structure in MHS and MHN subjects. They also suggest that the potential to use spin-labelled red blood cells as a screening protocol for MH deserves further investigation.

摘要

从六名恶性高热易感(MHS)和六名恶性高热正常(MHN)志愿者供体中分离出的自旋标记(7-、12-和16-二氧杂甾酸(DS)酸)红细胞膜,使用从37℃、9GHz电子顺磁共振光谱确定的序参数(S)和旋转相关时间(τr)进行表征。发现随着氟烷和苯甲醇样品浓度的增加,由于膜的流动性增加,这些参数会降低,并且MHS和MHN样品组之间的S和τr值存在显著差异,但对于两个样品组而言,外部流化剂存在与否时这些参数的差异并不显著。在没有这些流化剂的情况下,MHS和MHN在37℃时7-DS的S平均值和标准误差分别为0.643(2)和0.652(3),12-DS的分别为0.554(2)和0.563(3),16-DS的τr分别为2.139(12)和2.223(13)纳秒。与一些先前的报告相反,MHS组的S和τr值明显小于MHN组。这些观察结果修正并扩展了先前的报告,表明在没有流化剂的情况下观察到的S和τr值取决于MHS和MHN受试者的红细胞膜结构。它们还表明,使用自旋标记红细胞作为恶性高热筛查方案的潜力值得进一步研究。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验