Nakai K, Abe H, Matsuda N, Kobayashi M, Ikeda H, Sekiguchi S, Tsuchida E
Hokkaido Red Cross Blood Center, Sapporo, Japan.
Biomater Artif Cells Immobilization Biotechnol. 1992;20(2-4):447-51. doi: 10.3109/10731199209119667.
For the determination of stroma content in SFH, two analytical methods were developed, the HPLC-UV for phospholipids and the enzyme immunoassay for blood group antigen. These analytical methods were applied to evaluate three representative SFH preparations. The 36,000 x g centrifugation method was shown to contain higher amount of stroma components. On the other hand, the BMM-40 nm and the ultrafiltration method with a 100 kd membrane was shown to remove more than 99.7% of phospholipids and almost all of blood group antigen from hemoglobin solutions. These results demonstrated that these analytical methods were very useful in evaluating any highly purified hemoglobin solutions.