Arens S, Kraft C, Schlegel U, Printzen G, Perren S M, Hansis M
Klinik und Poliklinik für Unfallchirurgie, Universität Bonn.
Langenbecks Arch Chir Suppl Kongressbd. 1998;115(Suppl I):193-6.
With a standardised model we investigated the influence of two different surgical approaches to the rabbit tibia for plate osteosynthesis on resistance to local infection after postoperative inoculation of graduated concentrations of staphylococcus aureus at the implant. The infection rate for the minimally invasive plate osteosynthesis with insertion of the implant in closed, soft tissue tunneling technique was 25% (3/12 animals; ID50 = 6.2 x 10(6) CFU) and for the conventional open approach 38% (5/13 animals; ID50 = 2 x 10(6) CFU). This difference is statistically not significant (with P < 0.05).