Suppr超能文献

急性冠状动脉综合征患者6种心肌肌钙蛋白检测方法的评估

Evaluation of 6 cardiac troponin assays in patients with acute coronary syndrome.

作者信息

Saadeddin Salam M, Habbab Moh'd A, Siddieg Hisham H, Al Seeni Mohammed N, Tahery Ashraf B, Dafterdar Rofaida M

机构信息

Department of Pathology, Armed Forces Hospital, Riyadh, Kingdom of Saudi Arabia.

出版信息

Saudi Med J. 2003 Oct;24(10):1092-7.

Abstract

OBJECTIVE

An increasing body of evidence has demonstrated the value of strategies based on cardiac troponin (cTn) assays in the diagnosis, prognosis and monitoring of patients with acute coronary syndrome (ACS). We evaluated the performance and the practicability of 6 commercially available assays (5 cTnI and 1 cTnT) in patients with ACS.

METHODS

This study was carried out between October 2001 and June 2002 at Armed Forces Hospital in collaboration with Prince Sultan Cardiac Center, Riyadh, Kingdom of Saudi Arabia. Blood samples from 96 patients, 40 with and 56 without clinical evidence of myocardial injury, were used for the evaluation. Cardiac TnI assays were performed using 5 different immunoanalyzers AxSYM (Abbott Laboratories), Stratus CS (Dade Behring), ACS:180 (Bayer), Centaur (Bayer) and Immulite (Diagnostic Products Corporation) while cTnT was measured on the Elecsys (Roche) immunoanalyzer. The sensitivity, specificity and positive and negative predictive values (PV) were calculated for all assays. General and special features related to installation, routine operation, quality control and other various special parameters of each immunoanalyzer were evaluated (using the score of 1-5 for each parameter) and compared with those of other analyzers.

RESULTS

The highest reliability values were observed with Immulite, followed by AxSYM, then Stratus, then ACS:180, and Centaur, and lastly by Elecsys. The highest practicability values were observed with Elecsys, and Centaur, followed by AxSYM and the lowest values were observed with Stratus.

CONCLUSION

Considering the combined performance and practicability score, the difference between the 10% coefficient variation cut off value and the 99th percentile value, and the difference in the relative reactivities to the various cTnI forms, the most favorable values were observed with AxSYM, followed by Immulite and Elecsys, then Centaur and Stratus, and lastly by ACS:180.

摘要

目的

越来越多的证据表明,基于心肌肌钙蛋白(cTn)检测的策略在急性冠状动脉综合征(ACS)患者的诊断、预后评估及监测中具有重要价值。我们评估了6种市售检测方法(5种cTnI检测方法和1种cTnT检测方法)在ACS患者中的性能及实用性。

方法

本研究于2001年10月至2002年6月在沙特阿拉伯王国利雅得苏丹王子心脏中心合作的武装部队医院开展。采集了96例患者的血样,其中40例有心肌损伤临床证据,56例无心肌损伤临床证据,用于评估。使用5种不同的免疫分析仪AxSYM(雅培实验室)、Stratus CS(德灵)、ACS:180(拜耳)、Centaur(拜耳)和Immulite(诊断产品公司)进行心肌肌钙蛋白I检测,而使用Elecsys(罗氏)免疫分析仪检测心肌肌钙蛋白T。计算所有检测方法的敏感性、特异性、阳性和阴性预测值(PV)。评估了与各免疫分析仪的安装、常规操作、质量控制及其他各种特殊参数相关的一般和特殊特征(每个参数评分为1 - 5分),并与其他分析仪进行比较。

结果

Immulite的可靠性值最高,其次是AxSYM,然后是Stratus,接着是ACS:180和Centaur,最后是Elecsys。Elecsys和Centaur的实用性值最高,其次是AxSYM,Stratus的实用性值最低。

结论

综合性能和实用性评分、10%变异系数临界值与第99百分位数之间的差异以及对各种cTnI形式的相对反应性差异,AxSYM表现出最有利的值,其次是Immulite和Elecsys,然后是Centaur和Stratus,最后是ACS:180。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验