Suppr超能文献

一种评估长期植入仪器、未受限制的豚鼠气道功能参数的新方法。

A novel method to assess airway function parameters in chronically instrumented, unrestrained guinea-pigs.

作者信息

Santing R E, Meurs H, van der Mark T W, Remie R, Oosterom W C, Brouwer F, Zaagsma J

机构信息

Department of Pharmacology and Therapeutics, University Centre for Pharmacy, Groningen, The Netherlands.

出版信息

Pulm Pharmacol. 1992 Dec;5(4):265-72. doi: 10.1016/0952-0600(92)90069-s.

Abstract

A new method has been developed to measure airway functions in unanaesthetized, unrestrained guinea-pigs. The technique utilizes a specially designed pneumotachograph that is placed inside the trachea, and a saline-filled balloon, placed inside the pleural cavity. The pneumotachograph consists of a stainless steel cylinder with coaxial and perpendicular tubes attached to it, measuring the total pressure and the lateral pressure in the trachea, respectively. Via air-filled silicon conducting tubes, subcutaneously driven and permanently attached to the neck of the animal, the pressures are fed into a differential pressure transducer, yielding a pressure difference proportional to the airflow in the trachea. Via a saline-filled tubing, the pleural balloon is similarly attached to the neck of the animal, and pleural pressure (Ppl) is measured using a second pressure transducer. These data permit calculation of airway functions in conscious, unstressed animals. Control values for airway resistance (RAW), Ppl, tidal volume and respiratory frequency are all in the range of results reported previously for this species. A very significant correlation between RAW and Ppl (P < 0.001) was observed, indicating that sole Ppl-measurement can be used as a relatively simple and sensitive method to assess bronchial obstructive reactions in unrestrained guinea-pigs. Using a specially designed provocation cage, which allowed the animals to remain in a stress-free, unrestrained condition, the method has been successfully applied for the assessment of the dose-dependent bronchoconstrictor sensitivity to histamine as well as to allergen-induced early and late phase airway reactions.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

已开发出一种新方法来测量未麻醉、未受束缚的豚鼠的气道功能。该技术使用一个置于气管内的特殊设计的呼吸流速计,以及一个置于胸腔内的充生理盐水的气球。呼吸流速计由一个不锈钢圆柱体组成,其上连接有同轴和垂直的管子,分别测量气管内的总压力和侧向压力。通过皮下驱动并永久连接到动物颈部的充空气的硅导管,压力被输送到一个压差传感器,产生一个与气管内气流成比例的压力差。通过一根充生理盐水的管道,胸膜气球同样连接到动物颈部,并使用第二个压力传感器测量胸膜压力(Ppl)。这些数据允许计算清醒、无应激动物的气道功能。气道阻力(RAW)、Ppl、潮气量和呼吸频率的对照值均在先前报道的该物种结果范围内。观察到RAW和Ppl之间存在非常显著的相关性(P < 0.001),表明单独测量Ppl可作为一种相对简单且灵敏的方法来评估未受束缚的豚鼠的支气管阻塞反应。使用一个特殊设计的激发笼,使动物能够处于无应激、未受束缚的状态,该方法已成功应用于评估对组胺以及变应原诱导的早期和晚期气道反应的剂量依赖性支气管收缩敏感性。(摘要截短为250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验