Suppr超能文献

椎体成形术:骨水泥渗漏至椎间盘会增加相邻椎体新发骨折的风险。

Vertebroplasty: cement leakage into the disc increases the risk of new fracture of adjacent vertebral body.

作者信息

Lin Edward P, Ekholm Sven, Hiwatashi Akio, Westesson Per-Lennart

机构信息

Department of Radiology, Division of Diagnostic and Interventional Neuroradiology, University of Rochester Medical Center, Rochester, NY 14642, USA.

出版信息

AJNR Am J Neuroradiol. 2004 Feb;25(2):175-80.

Abstract

BACKGROUND AND PURPOSE

Patients successfully treated with vertebroplasty often return with new pain caused by a new vertebral body fracture. The new fractures often are adjacent to the vertebral bodies that were initially treated. In our clinical work, we have observed that cement leakage into the disk increases the risk of new fracture of the adjacent vertebral body. This study analyzed the risk of new fractures of adjacent vertebral bodies in relationship to cement leakage into the disk.

METHODS

This study was based on 38 patients with painful compression fractures treated with vertebroplasty. Patients who returned with new pain after initial successful vertebroplasty were evaluated by repeat MR imaging. We analyzed the incidence of new fractures of adjacent vertebral bodies in relationship to cement leakage into the disk that had occurred during the initial vertebroplasty.

RESULTS

Fourteen patients developed new fractures during the follow-up period. In 10 patients, the new fractures were associated with cement leakage into the disk, whereas four patients had new fractures that were not associated with cement leakage into the disk. This difference was statistically significant (P =.018). A detailed analysis showed that 58% of vertebral bodies adjacent to a disk with cement leakage fractured during the follow-up period compared with 12% of vertebral bodies adjacent to a disk without cement leakage (P <.0005).

CONCLUSION

Leakage of cement into the disk during vertebroplasty increases the risk of a new fracture of adjacent vertebral bodies.

摘要

背景与目的

经椎体成形术成功治疗的患者常因新的椎体骨折而再次出现疼痛。新骨折往往发生在最初接受治疗的椎体相邻部位。在我们的临床工作中,我们观察到骨水泥渗漏至椎间盘会增加相邻椎体发生新骨折的风险。本研究分析了与骨水泥渗漏至椎间盘相关的相邻椎体发生新骨折的风险。

方法

本研究基于38例行椎体成形术治疗疼痛性压缩骨折的患者。对初次椎体成形术成功后再次出现疼痛的患者进行重复磁共振成像评估。我们分析了与初次椎体成形术期间发生的骨水泥渗漏至椎间盘相关的相邻椎体新骨折的发生率。

结果

14例患者在随访期间出现新骨折。其中10例患者的新骨折与骨水泥渗漏至椎间盘有关,而4例患者的新骨折与骨水泥渗漏至椎间盘无关。这种差异具有统计学意义(P = 0.018)。详细分析显示,随访期间,与有骨水泥渗漏的椎间盘相邻的椎体有58%发生骨折,而与无骨水泥渗漏的椎间盘相邻的椎体有12%发生骨折(P < 0.0005)。

结论

椎体成形术期间骨水泥渗漏至椎间盘会增加相邻椎体发生新骨折的风险。

相似文献

2
Impact of cement leakage into disks on the development of adjacent vertebral compression fractures.
J Spinal Disord Tech. 2010 Feb;23(1):35-9. doi: 10.1097/BSD.0b013e3181981843.
3
Does filling the crack break more of the back?
AJNR Am J Neuroradiol. 2004 Feb;25(2):166-7.
4
[Risk factors of non-surgical vertebral fracture after percutaneous kyphoplasty of single segment thoracolumbar fracture].
Zhongguo Gu Shang. 2017 Sep 25;30(9):833-837. doi: 10.3969/j.issn.1003-0034.2017.09.010.
5
The risk of new osteoporotic vertebral compression fractures in the year after percutaneous vertebroplasty.
J Vasc Interv Radiol. 2006 Jan;17(1):71-6. doi: 10.1097/01.RVI.0000190910.43602.3C.
6
Cement leakage during vertebroplasty can be predicted on preoperative MRI.
AJR Am J Roentgenol. 2007 Apr;188(4):1089-93. doi: 10.2214/AJR.06.0903.
7
Vertebroplasty: only small cement volumes are required to normalize stress distributions on the vertebral bodies.
Spine (Phila Pa 1976). 2009 Dec 15;34(26):2865-73. doi: 10.1097/BRS.0b013e3181b4ea1e.
8
Incidence of subsequent vertebral fracture after kyphoplasty.
Spine (Phila Pa 1976). 2004 Oct 15;29(20):2270-6; discussion 2277. doi: 10.1097/01.brs.0000142469.41565.2a.
9
Percutaneous vertebral augmentation: an elevation in adjacent-level fracture risk in kyphoplasty as compared with vertebroplasty.
Spine J. 2007 Sep-Oct;7(5):575-82. doi: 10.1016/j.spinee.2006.10.020. Epub 2007 Jan 24.

引用本文的文献

3
Modalities of failure of cement-augmented pedicle screws.
Eur Spine J. 2025 Apr 26. doi: 10.1007/s00586-025-08792-2.
6
Enhancing percutaneous kyphoplasty efficacy in elderly osteoporotic fractures through optimal cement filling ratio.
Front Endocrinol (Lausanne). 2024 May 10;15:1359550. doi: 10.3389/fendo.2024.1359550. eCollection 2024.
10
Assessment of Cement Leakage in Decompressed Percutaneous Kyphoplasty.
J Clin Med. 2024 Jan 8;13(2):345. doi: 10.3390/jcm13020345.

本文引用的文献

2
Percutaneous vertebroplasty for severe osteoporotic vertebral body compression fractures.
Radiology. 2002 Apr;223(1):121-6. doi: 10.1148/radiol.2231010234.
3
Percutaneous vertebroplasty for osteoporotic compression fractures: quantitative prospective evaluation of long-term outcomes.
J Vasc Interv Radiol. 2002 Feb;13(2 Pt 1):139-48. doi: 10.1016/s1051-0443(07)61930-7.
5
Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty.
Spine (Phila Pa 1976). 2001 Jul 15;26(14):1547-54. doi: 10.1097/00007632-200107150-00009.
6
The biomechanics of vertebroplasty. The effect of cement volume on mechanical behavior.
Spine (Phila Pa 1976). 2001 Jul 15;26(14):1537-41. doi: 10.1097/00007632-200107150-00007.
7
New technologies in spine: kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures.
Spine (Phila Pa 1976). 2001 Jul 15;26(14):1511-5. doi: 10.1097/00007632-200107150-00002.
8
Root and spinal cord compression from methylmethacrylate vertebroplasty.
Spine (Phila Pa 1976). 2001 Jul 1;26(13):E300-2. doi: 10.1097/00007632-200107010-00021.
9
Long-term observations of vertebral osteoporotic fractures treated by percutaneous vertebroplasty.
Rheumatology (Oxford). 2000 Dec;39(12):1410-4. doi: 10.1093/rheumatology/39.12.1410.
10

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验