与模块化后稳定型膝关节置换相关的骨溶解和松动发生率。5至14年的结果。

The rates of osteolysis and loosening associated with a modular posterior stabilized knee replacement. Results at five to fourteen years.

作者信息

Lachiewicz Paul F, Soileau Elizabeth S

机构信息

Department of Orthopaedics, University of North Carolina, Chapel Hill, 242 Burnett Womack Building, CB 7055, Chapel Hill, NC 27599, USA.

出版信息

J Bone Joint Surg Am. 2004 Mar;86(3):525-30. doi: 10.2106/00004623-200403000-00010.

Abstract

BACKGROUND

Osteolysis and increased polyethylene wear have been reported in association with several designs of modular total knee prostheses. The purpose of the present study was to evaluate a modular posterior stabilized prosthesis to determine its clinical performance as well as the rates of component loosening and osteolysis.

METHODS

We performed a prospective, consecutive study of 193 knees in 131 patients who were managed with the modular Insall-Burstein II posterior stabilized total knee prosthesis by one surgeon. The mean age of the patients at the time of surgery was sixty-eight years, and the mean duration of follow-up was seven years (range, five to fourteen years). Clinical evaluation was performed with use of standard knee-scoring systems. Radiographs were evaluated for the presence of radiolucent lines, osteolysis, and loosening.

RESULTS

The overall result (as determined with the Hospital for Special Surgery scoring system) was rated as excellent for 112 knees, good for sixty, fair for fifteen, and poor for six. The mean postoperative flexion was 112 degrees. No clinical or radiographic loosening of the tibial component was noted. Eight knees had osteolytic lesions of the tibia. Thin, incomplete, nonprogressive radiolucent lines were noted around thirty tibial components (16%). There were three reoperations.

CONCLUSIONS

Despite previous reports of osteolysis, polyethylene wear, and loosening in association with some modular total knee implant designs, there was no loosening in this series of posterior stabilized total knee replacements and only eight knees had tibial osteolysis after a mean duration of follow-up of seven years. We believe that total knee arthroplasties that are performed with use of cemented modular posterior stabilized components can have a high rate of intermediate-term success.

LEVEL OF EVIDENCE

Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.

摘要

背景

据报道,多种模块化全膝关节假体设计与骨质溶解及聚乙烯磨损增加有关。本研究的目的是评估一种模块化后稳定型假体,以确定其临床性能以及组件松动和骨质溶解的发生率。

方法

我们对131例患者的193个膝关节进行了一项前瞻性、连续性研究,这些患者均由一名外科医生采用模块化Insall-Burstein II后稳定型全膝关节假体进行治疗。患者手术时的平均年龄为68岁,平均随访时间为7年(范围为5至14年)。使用标准膝关节评分系统进行临床评估。对X线片进行评估,以确定是否存在透亮线、骨质溶解和松动。

结果

总体结果(根据特种外科医院评分系统确定)评为优的有112个膝关节,评为良的有60个,评为可的有15个,评为差的有6个。术后平均屈曲度为112度。未发现胫骨组件有临床或影像学松动。8个膝关节有胫骨溶骨病变。在30个胫骨组件周围发现了薄的、不完整的、无进展的透亮线(16%)。有3例再次手术。

结论

尽管此前有报道称某些模块化全膝关节植入物设计与骨质溶解、聚乙烯磨损和松动有关,但在这一系列后稳定型全膝关节置换术中未出现松动,平均随访7年后只有8个膝关节出现胫骨骨质溶解。我们认为,使用骨水泥固定的模块化后稳定型组件进行的全膝关节置换术可以有较高的中期成功率。

证据水平

治疗性研究,IV级(病例系列[无或历史对照组])。有关证据水平的完整描述,请参阅作者须知。