Karpinia K, Magnusson I, Gibbs C, Yang M C K
Periodontal Disease Research Center, University of Florida, Gainesville, FL 32610, USA.
J Clin Periodontol. 2004 Mar;31(3):173-6. doi: 10.1111/j.0303-6979.2004.00464.x.
Current interest in the assessment of probing attachment level measurements has been stimulated by recent introduction of novel periodontal probes as well as by the reclassification of periodontal diseases. Clinical attachment level (CAL) is currently the "gold standard" for diagnosing and monitoring periodontal diseases.
To evaluate the performance of the newly introduced cementoenamel junction (CEJ) Probe in detecting CAL using the CEJ as a fixed reference point, and to compare the CEJ Probe with the Florida Disk Probe and a standard Manual Probe (North Carolina Probe).
Three examiners probed 12 periodontal patients to determine intra- and inter-consistency of both the probes and the examiners, over a 4-week time interval. Subjects ranged in age from 22 to 74 years. The experimental design was structured to balance the intra- and inter-examiner consistency at the same site during the two visits.
Using the PROC MIXED of SAS, a strong interaction (p<0.001) between the examiner and probes was found. The consistency of probing (repeatability of measurements) depended upon the type of periodontal probe used as well as the skill (experience) of the examiner. Overall, the CEJ Probe displayed a more consistent performance. The CEJ Probe demonstrated greater intra-examiner consistency than the Disk Probe for two examiners (p<0.01). The CEJ Probe also showed increased inter-examiner consistency (p<0.01).
The CEJ Probe has the potential to offer the dental team an efficient, accurate mechanism to chart and monitor attachment level measurements over time. Additional studies, using large numbers of examiners, are needed to assess more clearly the performance of each individual probe.
近期新型牙周探针的引入以及牙周疾病的重新分类激发了当前对探测附着水平测量评估的兴趣。临床附着水平(CAL)目前是诊断和监测牙周疾病的“金标准”。
以釉牙骨质界(CEJ)作为固定参考点,评估新引入的釉牙骨质界探针在检测CAL方面的性能,并将CEJ探针与佛罗里达盘状探针和标准手动探针(北卡罗来纳探针)进行比较。
三名检查者在4周的时间间隔内对12名牙周病患者进行探测,以确定探针和检查者的内部及相互之间的一致性。受试者年龄在22岁至74岁之间。实验设计旨在平衡两次就诊期间同一部位检查者内部及相互之间的一致性。
使用SAS的PROC MIXED程序,发现检查者与探针之间存在强烈的交互作用(p<0.001)。探测的一致性(测量的可重复性)取决于所使用的牙周探针类型以及检查者的技能(经验)。总体而言,CEJ探针表现出更一致的性能。对于两名检查者,CEJ探针在检查者内部的一致性高于盘状探针(p<0.01)。CEJ探针在检查者之间也显示出更高的一致性(p<0.01)。
CEJ探针有可能为牙科团队提供一种高效、准确的机制,用于长期绘制和监测附着水平测量。需要进行更多使用大量检查者的研究,以更清楚地评估每种探针的性能。