心室内环形补片修补术后左心室中期功能的放射性核素研究

Radionuclide study of mid-term left ventricular function after endoventricular circular patch plasty.

作者信息

Fujii Hiromichi, Ohashi Hirokazu, Tsutsumi Yasushi, Kawai Takahiro, Iino Kenji, Onaka Masateru

机构信息

Department of Cardiovascular Surgery, Fukui Cardiovascular Center, Shinbo 2-228, Fukui city 910-0833, Japan.

出版信息

Eur J Cardiothorac Surg. 2004 Jul;26(1):125-8. doi: 10.1016/j.ejcts.2004.03.008.

Abstract

OBJECTIVE

Although the early result of endoventricular circular patch plasty (EVCPP) has been reported, few are seen about the long-term results. We studied left ventricular (LV) function in the early and mid-term periods after EVCPP with electrocardiographic-gated single photon emission computed tomography (Gated SPECT).

METHODS

Consecutive 14 patients with LV asynergy after myocardial infarction, who had the EVCPP procedure, were studied by Gated SPECT. Mean age of patients was 67+/-10 years. Gated SPECT images were obtained and LV end-diastolic volume index (EDVI), LV end-systolic volume index (ESVI) and ejection fraction (EF) were studied with QGS(+) program. Gated SPECT study was performed before surgery, early (23 days) and mid-term periods (32 months) after surgery.

RESULTS

EDVI changed significantly from preoperative value to early postoperative value (107+/-39 to 72+/-37 ml/m(2), P < 0.01). There was no significant difference between early and mid-term postoperative values. ESVI also changed significantly from preoperative value to early postoperative value, and from early value to mid-term postoperative value (78+/-37 to 51+/-34 to 47+/-35 ml/m(2), P < 0.05, respectively). EF increased significantly from preoperative value to early postoperative value, and from early value to mid-term postoperative value (30+/-10 to 35+/-13 to 45+/-18%, P < 0.05, respectively).

CONCLUSIONS

Direct influence of EVCPP brought significant improvement of LV function in early period. Further decrease of ESVI and increase of EF were noticed from early period to mid-term period. This result suggest that the effect of EVCPP sustains long and yields reverse LV remodeling.

摘要

目的

尽管已有关于心室内环形补片成形术(EVCPP)早期结果的报道,但关于其长期结果的报道较少。我们采用心电图门控单光子发射计算机断层扫描(门控SPECT)研究了EVCPP术后早期和中期的左心室(LV)功能。

方法

对连续14例行EVCPP手术的心肌梗死后左心室运动不协调患者进行门控SPECT研究。患者平均年龄为67±10岁。获取门控SPECT图像,并使用QGS(+)程序研究左心室舒张末期容积指数(EDVI)、左心室收缩末期容积指数(ESVI)和射血分数(EF)。在手术前、术后早期(23天)和中期(32个月)进行门控SPECT研究。

结果

EDVI从术前值到术后早期值有显著变化(107±39至72±37 ml/m²,P<0.01)。术后早期和中期值之间无显著差异。ESVI也从术前值到术后早期值,以及从早期值到术后中期值有显著变化(78±37至51±34至47±35 ml/m²,P分别<0.05)。EF从术前值到术后早期值,以及从早期值到术后中期值显著增加(30±10至35±13至45±18%,P分别<0.05)。

结论

EVCPP的直接影响在早期使左心室功能有显著改善。从早期到中期,ESVI进一步降低,EF增加。这一结果表明EVCPP的效果持续时间长,并能产生左心室逆向重构。