Turck M D, Lang B R, Wilcox D E, Meiers J C
Naval Dental School, Bethesda, Maryland.
Int J Prosthodont. 1992 Jul-Aug;5(4):367-72.
The Michigan Computer-Graphics Coordinate Measurement System (MCGCMS) was used to determine the dimensional accuracy of dentures processed by three different techniques: conventional heat compression, microwave, and visible-light activation. Standardized dentures were fabricated from casts made in an RTV silicone mold. All casts were duplicated with hydrocolloid and 42 dentures were made (ie, 14 dentures for each technique). The MCGCMS measured 22 points on two frontal planes to compare master casts to dentures. The results showed no significant difference in overall dimensional accuracy. At specific sites, however, the visible-light-activated technique produced significantly more flange distortion than did either the conventional or microwave techniques.
密歇根计算机图形坐标测量系统(MCGCMS)用于确定通过三种不同技术加工的假牙的尺寸精度:传统热压、微波和可见光活化。标准化假牙由在室温硫化硅橡胶模具中制作的铸模制成。所有铸模均用水胶体复制,并制作了42副假牙(即每种技术制作14副假牙)。MCGCMS在两个额平面上测量了22个点,以比较母模和假牙。结果表明,整体尺寸精度没有显著差异。然而,在特定部位,可见光活化技术产生的边缘变形比传统技术或微波技术都要明显得多。