Wavefront sensing represents a novel diagnostic method to measure high-order aberrations. This technology has primarily been used in conjunction with excimer laser technology for performing wavefront-guided custom ablations, targeted at the correction of low- and high-order aberrations, while not inducing further high-order aberrations.Although this field of application remains predominant, wavefront sensing may also be used successfully in the diagnosis and detection of vision problems, as reported by patients, related to the presence of high-order aberrations. Currently, wavefront analysis represents the only diagnostic tool clinically available to explore all of the refraction and diffraction problems generated by the presence of high-order aberrations.

摘要

波前传感是一种用于测量高阶像差的新型诊断方法。这项技术主要与准分子激光技术结合使用,用于进行波前引导的定制消融,旨在矫正低阶和高阶像差,同时不诱发进一步的高阶像差。尽管该应用领域仍然占据主导地位,但正如患者所报告的,波前传感也可成功用于诊断和检测与高阶像差存在相关的视力问题。目前,波前分析是临床上唯一可用于探究由高阶像差产生的所有折射和衍射问题的诊断工具。

相似文献

1
Diagnostic use of ocular wavefront sensing.
Ophthalmol Clin North Am. 2004 Jun;17(2):129-33, v. doi: 10.1016/j.ohc.2004.02.007.
2
The future of wavefront sensing and customization.
Ophthalmol Clin North Am. 2004 Jun;17(2):247-60, viii. doi: 10.1016/j.ohc.2004.03.003.
3
Alcon CustomCornea platform with LADARWave and LADARVision.
Ophthalmol Clin North Am. 2004 Jun;17(2):161-72, vi. doi: 10.1016/j.ohc.2004.02.006.
4
Aberrometry: basic science and clinical applications.
Bull Soc Belge Ophtalmol. 2006(302):197-213.
5
Comparison of wavefront sensing devices.
Ophthalmol Clin North Am. 2004 Jun;17(2):119-27, v. doi: 10.1016/j.ohc.2004.02.003.
6
Wavefront-guided customized corneal ablation.
Curr Opin Ophthalmol. 2008 Jul;19(4):314-20. doi: 10.1097/ICU.0b013e328302ccae.
7
The optics of wavefront sensing.
Ophthalmol Clin North Am. 2004 Jun;17(2):111-7, v. doi: 10.1016/j.ohc.2004.02.004.
9
[Aberrometer systems in laser refractive surgery].
Klin Oczna. 2005;107(10-12):719-21.

引用本文的文献

1
Wavefront Aberrometry in Pseudophakic Patients Before and After Vitrectomy for Bothersome Floaters.
J Vitreoretin Dis. 2025 Apr 29:24741264251333200. doi: 10.1177/24741264251333200.
2
Automated vs. human evaluation of corneal staining.
Graefes Arch Clin Exp Ophthalmol. 2022 Aug;260(8):2605-2612. doi: 10.1007/s00417-022-05574-0. Epub 2022 Mar 31.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验