Suppr超能文献

大鼠后肢缺血模型的闪烁扫描评估。

Evaluation by scintigraphy of hindlimb ischemia in a rat model.

作者信息

Babuccu Orhan, Peksoy Irfan, Hosnuter Mubin, Kargi Eksal, Babuccu Berfu

机构信息

Department of Plastic and Reconstructive Surgery, Zonguldak Karaelmas University Faculty of Medicine, Zonguldak, Turkey.

出版信息

J Reconstr Microsurg. 2004 Jul;20(5):405-10. doi: 10.1055/s-2004-830005.

Abstract

The subject of ischemia-reperfusion has commonly been studied in rat hindlimb models. Unfortunately, in these experiments, the ischemia procedures lack standardization. For this reason, the authors evaluated the reliability of rat ischemia models described in the literature using scintigraphy. The study comprised six groups. Each consisted of ten male Wistar rats; five of them underwent methoxy-isobutyl-isonitrile (MIBI) scintigraphy, which is specific for muscle, and the others underwent methylene diphosphanate (MDP) scintigraphy, which is specific for bone. In Group 1, only the iliac artery was ligated; in Group 2, the iliac artery and its branches, except for the superficial epigastric artery, were ligated; in Group 3, the iliac artery and vein were ligated; in Group 4, the iliac artery and all branches, including the superficial epigastric artery, were ligated; in Group 5, in addition to ligation of the iliac artery and its branches, the skin was incised circumferentially around the pelvic girdle; in Group 6, a tourniquet was applied to the limb at the pelvic level. After 2-hr warm ischemia, a radioactive tracer was injected intravenously. In the MIBI group, images were taken at the twentieth minute and second hour after injection, and in the MDP group, at the fifth minute and third hour after injection. The radioactivity in both hind limbs of the animal was measured, and the ratio of the control to the ischemic limb was calculated. In the first five groups, there was no necrosis in the ischemic limb at the end of 2 weeks. The measured radioactivity in the ischemic limb was lower than that of the control limb in all groups. The ratio of activity obtained from the control limb to that of the ischemic limb in the tourniquet group was significantly higher, compared to other groups in both MIBI and MDP evaluations (p < 0.005). Significant ischemia was also seen in the skin incision group (Group 5). A low-flow state was observed in the ischemic limb in Groups 1-4 using both scintigraphic modalities. The tourniquet method (Group 6) provided almost complete limb ischemia, compared to other arterial ligation methods, and it is practical to use for complete ischemia when studying the physiology of replantation or free flaps.

摘要

缺血再灌注的课题通常在大鼠后肢模型中进行研究。不幸的是,在这些实验中,缺血程序缺乏标准化。因此,作者使用闪烁扫描术评估了文献中描述的大鼠缺血模型的可靠性。该研究包括六组。每组由十只雄性Wistar大鼠组成;其中五只接受了对肌肉特异的甲氧基异丁基异腈(MIBI)闪烁扫描术,其他五只接受了对骨骼特异的亚甲基二膦酸盐(MDP)闪烁扫描术。在第一组中,仅结扎髂动脉;在第二组中,结扎髂动脉及其分支,但不包括腹壁浅动脉;在第三组中,结扎髂动脉和静脉;在第四组中,结扎髂动脉及其所有分支,包括腹壁浅动脉;在第五组中,除了结扎髂动脉及其分支外,还在骨盆带周围环形切开皮肤;在第六组中,在骨盆水平对肢体应用止血带。在2小时的热缺血后,静脉注射放射性示踪剂。在MIBI组中,在注射后第20分钟和第2小时进行成像,在MDP组中,在注射后第5分钟和第3小时进行成像。测量动物双后肢的放射性,并计算对照肢体与缺血肢体的比值。在前五组中,在2周结束时缺血肢体没有坏死。在所有组中,缺血肢体中测得的放射性均低于对照肢体。在MIBI和MDP评估中,与其他组相比,止血带组中对照肢体与缺血肢体的活性比值显著更高(p<0.005)。在皮肤切开组(第五组)中也观察到明显的缺血。使用两种闪烁扫描方式在第1-4组的缺血肢体中均观察到低血流状态。与其他动脉结扎方法相比,止血带方法(第六组)提供了几乎完全的肢体缺血,并且在研究再植或游离皮瓣的生理学时用于完全缺血是实用的。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验