Kanaya N, Asaoka S, Sakanaka S, Maezawa H
Photon Factory, High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba 305, Japan.
J Synchrotron Radiat. 1998 May 1;5(Pt 3):395-7. doi: 10.1107/S0909049597015100.
The ultrahigh-vacuum (UHV) protection system at the 2.5 GeV synchrotron radiation source (positron storage ring) at the Photon Factory allows the intense-photon-flux wiggler beamlines to operate safely during synchrotron radiation experiments for a long time. There are six high-power wiggler/undulator beamlines that provide intense photon-flux beams to the experimental hall. In the case of a possible instantaneous vacuum failure at the experimental hall, the intense photon-flux radiation from the wiggler could cause a meltdown of the titanium-alloy fast-closing valve. The authors have developed a UHV protection system. Upon a vacuum failure, the protection system can dump the positron beam by turning off the RF power in the four RF klystrons (150 kW maximum), and then initiate a blade closure of the fast-closing valve. In this paper, the operational performance of the vacuum protection system for the intense-photon-flux wiggler beamlines is evaluated and discussed regarding the actual vacuum deterioration downstream of a beamline at the experimental hall.
光子工厂2.5 GeV同步辐射源(正电子储存环)的超高真空(UHV)保护系统,可使强光子通量摆动器光束线在同步辐射实验期间长时间安全运行。有六条高功率摆动器/波荡器光束线为实验大厅提供强光子通量光束。万一实验大厅可能出现瞬时真空故障,摆动器产生的强光子通量辐射可能会导致钛合金快速关闭阀熔化。作者开发了一种超高真空保护系统。真空故障发生时,该保护系统可通过关闭四个射频速调管(最大150 kW)中的射频功率来倾卸正电子束,然后启动快速关闭阀的叶片关闭。本文针对实验大厅光束线下游实际的真空恶化情况,对强光子通量摆动器光束线的真空保护系统的运行性能进行了评估和讨论。