Bahrdt J, Gaupp A, Ingold G, Scheer M, Gudat W
BESSYmbH, Lentzeallee 100, 14195 Berlin, Germany.
J Synchrotron Radiat. 1998 May 1;5(Pt 3):443-4. doi: 10.1107/S0909049597013757.
The high-brilliance synchrotron radiation source BESSY II will provide space for the installation of 14 insertion devices. At the time of writing (July 1997), eight insertion devices are funded. The first light for use by scientists will be available in January 1999. The undulators are designed for a scanning operation in parallel with the monochromator. This modus requires tight tolerances concerning the drive system. The first insertion device to be installed, a U-49 undulator, has been assembled and magnetically measured. The r.m.s. phase error is 2 degrees. An endpole configuration using coils with less than 64 amp-turns makes the angular kick smaller than +/-3 micro rad over a gap range 15-50 mm.