Suppr超能文献

全膝关节置换术中髌骨关节对称性的触觉评估准确性

Accuracy of haptic assessment of patellar symmetry in total knee arthroplasty.

作者信息

DeOrio James K, Peden John P

机构信息

Department of Orthopedic Surgery, Mayo Clinic, Jacksonville, FL 32224, USA.

出版信息

J Arthroplasty. 2004 Aug;19(5):629-34. doi: 10.1016/j.arth.2003.12.066.

Abstract

Resection resulting in asymmetrically thick patellar arthroplasty in knee arthroplasty may lead to increased compression forces, wear, fracture, or loss of quadriceps power. Assessing the cut patella between the thumb and forefinger (haptic assessment) represents a convenient way to recognize asymmetry. In 2 test series, 8 orthopedic surgeons evaluated 24 precut solid foam patellae of varying asymmetric thickness by feeling the patella between thumb and forefinger, without visualization. Of 384 responses, in 73.2% asymmetry was underestimated, 10.4% assessments were exact, and in 16.4% asymmetry was overestimated. Specifically, 35.9% were correct within 1 mm, 60.7% within 2 mm, 81% within 3 mm, and 91.4% within 4 mm. The thickest half of the patella was correctly identified in 90.6% of responses. Haptic assessment of patellar symmetry is a useful technique in knee arthroplasty.

摘要

在膝关节置换术中,切除导致髌股关节置换不对称增厚可能会导致压力增加、磨损、骨折或股四头肌力量丧失。用拇指和食指评估切割后的髌骨(触觉评估)是识别不对称的一种便捷方法。在2个测试系列中,8名骨科医生通过在拇指和食指之间触摸髌骨来评估24个预先切割的不同不对称厚度的实心泡沫髌骨,无需可视化。在384次评估中,73.2%的不对称被低估,10.4%的评估准确,16.4%的不对称被高估。具体而言,35.9%在1毫米内正确,60.7%在2毫米内正确,81%在3毫米内正确,91.4%在4毫米内正确。在90.6%的评估中正确识别出了髌骨最厚的一半。髌骨对称性的触觉评估在膝关节置换术中是一项有用的技术。