Milavec-Puretić Visnja
Department of Dermatology and Venerology, University Hospital Zagreb, Zagreb, Croatia.
Arh Hig Rada Toksikol. 2004 Jun;55(2-3):193-6.
This paper describes a study of hypersensitivity and tissue reaction to loosened metal implants in 40 patients who underwent repeated hip arthroplasty. Metal sensitivity was tested using a standard cutaneous patch test. Nine patients were positive for chromium, nickel, cobalt, metal rust, endoprosthesis scrapings or combinations of these allergens. Patients with positive or negative patch test did not differ in terms of their age, sex, primary diagnosis, number of endoprosthesis revisions, length of implant function, presence of other metal parts around the implant, circulating immunocomplexes, and histological appearance of the tissue around the implant. In conclusion, stainless steel endoprostheses are safe for revised hip arthroplasty, and hypersensitivity to metals probably does not play a significant role in the loosening of endoprosthesis.
本文描述了一项针对40例行反复髋关节置换术患者的金属植入物松动后的超敏反应及组织反应的研究。采用标准皮肤斑贴试验检测金属敏感性。9例患者对铬、镍、钴、金属锈、假体碎片或这些过敏原的组合呈阳性反应。斑贴试验阳性或阴性的患者在年龄、性别、初步诊断、假体翻修次数、植入物功能时长、植入物周围其他金属部件的存在情况、循环免疫复合物以及植入物周围组织的组织学表现方面并无差异。总之,不锈钢假体用于翻修髋关节置换术是安全的,对金属的超敏反应可能在假体松动中不起重要作用。