用于低温生活污水处理的UASB反应器:传统UASB与UASB-滤池复合式反应器的比较

UASB reactor for domestic wastewater treatment at low temperatures: a comparison between a classical UASB and hybrid UASB-filter reactor.

作者信息

Lew B, Tarre S, Belavski M, Green M

机构信息

Faculty of Civil and Environmental Engineering, Technion Haifa, Israel.

出版信息

Water Sci Technol. 2004;49(11-12):295-301.

Abstract

The performance of an upflow anaerobic sludge blanket (UASB) reactor and a hybrid UASB-filter reactor was investigated and compared for the treatment of domestic wastewater at different operational temperatures (28, 20, 14 and 10 degrees C) and loading rates. For each temperature studied a constant CODt removal was observed as long as the upflow velocity was lower than 0.35 m/h. At these upflow velocities similar removals were observed for both reactor types at 28 and 20 degrees C, 82 and 72% respectively. However, at 14 and 10 degrees C the UASB reactor showed a better COD removal (70% and 48%, respectively) than the hybrid reactor (60% and 38%). COD removal resulted from biological degradation and solids accumulation in the reactors. At 28 degrees C, a constant 200 g sludge mass was observed in both reactors and COD removal was attributed to biological degradation only. At lower temperatures, solids accumulation was observed in addition to biological degradation with an increase in reactor sludge as the temperature decreased. The decrease in biological degradation at lower temperatures was offset by solids accumulation and explains the similar overall COD removal efficiency observed at 28 degrees C, 20 degrees C and 14 degrees C. The decrease in temperature was also followed by an increase in the effluent TSS concentration in both reactors. At 14 and 10 degrees C a lower effluent TSS concentration and better performance was observed in the UASB reactor.

摘要

研究并比较了上流式厌氧污泥床(UASB)反应器和复合UASB-滤池反应器在不同运行温度(28、20、14和10摄氏度)及负荷率下处理生活污水的性能。对于所研究的每个温度,只要上流速度低于0.35米/小时,就能观察到稳定的化学需氧量(COD)去除率。在这些上流速度下,两种反应器在28摄氏度和20摄氏度时的去除率相似,分别为82%和72%。然而,在14摄氏度和10摄氏度时,UASB反应器的COD去除率(分别为70%和48%)比复合反应器(60%和38%)更高。COD去除是由生物降解和反应器内的固体物质积累导致的。在28摄氏度时,两个反应器内的污泥质量均稳定在200克,COD去除仅归因于生物降解。在较低温度下,除了生物降解外还观察到固体物质积累,且随着温度降低反应器污泥量增加。较低温度下生物降解的减少被固体物质积累所抵消,这就解释了在28摄氏度、20摄氏度和14摄氏度时观察到的总体COD去除效率相似的现象。温度降低还导致两个反应器的出水总悬浮固体(TSS)浓度增加。在14摄氏度和10摄氏度时,UASB反应器的出水TSS浓度更低且性能更好。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验