Different latex aeroallergen size distributions between powdered surgical and examination gloves: significance for environmental avoidance.

作者信息

Brown Robert H, Taenkhum Kanika, Buckley Timothy J, Hamilton Robert G

机构信息

Department of Environmental Health Sciences, Johns Hopkins University Bloomberg School of Public Health, Baltimore, MD 21205, USA.

出版信息

J Allergy Clin Immunol. 2004 Aug;114(2):358-63. doi: 10.1016/j.jaci.2004.04.003.

Abstract

BACKGROUND

Proactive medical institutions implement latex allergen avoidance to protect workers and patients with latex allergy and to prevent latex sensitization in these groups by creating latex-safe environments that include replacement of natural rubber latex examination and surgical gloves, especially those that are powdered, with synthetic alternatives. We have hypothesized that an apparent decreasing trend in new latex allergy cases in hospitals using only synthetic examination gloves but the occasional powdered latex surgical glove might result from constitutive differences in allergen content (particle size distribution and quantity) between powdered surgical gloves and examination gloves.

OBJECTIVE

Because aerodynamic particle size determines where inhaled airborne allergen deposits in the airway, the aim of this study was to investigate the differential particle size distribution of latex allergen released from powdered latex examination and surgical gloves.

METHODS

Powdered and nonpowdered latex examination and surgical gloves were processed to create an aerosol in a glove box equipped with air sampling equipment capable of total particle number and mass measurements. Air particulate generated in the glove box was collected on impactors with less than 2.5-microm, 2.5- to 10-microm, and greater than 10-microm particle size limits (4 L/min for 4 hours). All filters were extracted, and latex allergen was quantified by using a latex-CAP inhibition assay with a human IgE anti-latex serum pool.

RESULTS

Latex aeroallergen on powdered sterile surgical gloves resided primarily on particles greater than 10 microm in size (P <.006). In contrast, powdered examination gloves released the highest total latex aeroallergen content, with 68% of the particles sized in the respirable 2.5- to 10-microm range and carrying 56% of the airborne latex allergen.

CONCLUSIONS

Significantly lower quantities and larger sizes of latex allergen-containing particles released from surgical gloves provides one potential explanation as to why an apparent decrease in new cases of latex allergy can occur in hospitals that successfully replace latex examination gloves with synthetic gloves but continue occasional use of powdered surgical gloves.

摘要

背景

积极主动的医疗机构通过营造乳胶安全环境来避免乳胶过敏原,以保护乳胶过敏的工作人员和患者,并防止这些人群发生乳胶致敏,这包括用合成替代品替换天然橡胶乳胶检查手套和手术手套,尤其是那些含粉的手套。我们推测,在仅使用合成检查手套但偶尔使用含粉乳胶手术手套的医院中,新的乳胶过敏病例出现明显下降趋势,可能是由于含粉手术手套和检查手套在过敏原含量(颗粒大小分布和数量)上存在本质差异。

目的

由于空气动力学颗粒大小决定了吸入的空气传播过敏原在气道中的沉积位置,本研究旨在调查含粉乳胶检查手套和手术手套释放的乳胶过敏原的差异颗粒大小分布。

方法

对含粉和无粉的乳胶检查手套及手术手套进行处理,在配备有能够进行总颗粒数和质量测量的空气采样设备的手套箱中产生气溶胶。手套箱中产生的空气颗粒物收集在颗粒大小限制分别小于2.5微米、2.5至10微米和大于10微米的冲击器上(4升/分钟,持续4小时)。提取所有过滤器,并用含人IgE抗乳胶血清库的乳胶CAP抑制试验对乳胶过敏原进行定量。

结果

含粉无菌手术手套上的乳胶气传过敏原主要存在于尺寸大于10微米的颗粒上(P<.006)。相比之下,含粉检查手套释放的乳胶气传过敏原总量最高,68%的颗粒尺寸在可吸入的2.5至10微米范围内,携带了56%的空气传播乳胶过敏原。

结论

手术手套释放的含乳胶过敏原颗粒数量显著减少且尺寸更大,这为为何在成功用合成手套替代乳胶检查手套但仍偶尔使用含粉手术手套的医院中,新的乳胶过敏病例明显减少提供了一种潜在解释。