Suppr超能文献

Randomized clinical trial of continuous sutures or non-penetrating clips for radiocephalic arteriovenous fistula.

作者信息

Zeebregts C J, van den Dungen J J A M, van Det R J, Verhoeven E L G, Geelkerken R H, van Schilfgaarde R

机构信息

Department of Surgery, University Hospital Groningen, Groningen, The Netherlands.

出版信息

Br J Surg. 2004 Nov;91(11):1438-42. doi: 10.1002/bjs.4719.

Abstract

BACKGROUND

Despite several modifications to the original design, patency rates of radiocephalic arteriovenous fistulas have changed little since the first report in 1966. The use of non-penetrating clips for vascular anastomosis on the outcome of such fistulas was studied.

METHODS

Between January 2000 and August 2003, 107 primary radiocephalic fistulas were constructed in 98 patients. The vascular anastomoses were performed at random with either sutures (n = 56) or clips (n = 51).

RESULTS

Although there were trends for better primary and primary assisted patency of clipped fistulas, the differences were not statistically significant. The 6-month primary patency rate was 61 per cent with sutures and 69 per cent with clips (P = 0.393). The mean(s.d.) primary patency was 315(306) and 285(285) days for clipped and sutured fistulas respectively. With regard to secondary patency, clipped fistulas were better (P = 0.009). The mean(s.d.) secondary patency was 435(376) and 344(316) days for clipped and sutured fistulas, respectively. There were no significant differences in flow characteristics, number of revisions or other morbidity.

CONCLUSION

This randomized clinical trial provided further evidence that the use of vascular clips may improve the patency rate of radiocephalic arteriovenous fistulas for haemodialysis.

摘要

相似文献

2
Operative salvage of radiocephalic arteriovenous fistulas by formation of a proximal neoanastomosis.
J Vasc Surg. 2011 Jul;54(1):168-73. doi: 10.1016/j.jvs.2010.12.050. Epub 2011 Mar 2.
4
Outcome of primary radiocephalic fistula for haemodialysis.
Br J Surg. 1999 Feb;86(2):211-6. doi: 10.1046/j.1365-2168.1999.01007.x.
6
Creating radiocephalic arteriovenous fistulas: technical and functional success.
J Am Coll Surg. 2009 Mar;208(3):419-25. doi: 10.1016/j.jamcollsurg.2008.11.015. Epub 2009 Jan 21.
7
Radiocephalic wrist arteriovenous fistula for hemodialysis: meta-analysis indicates a high primary failure rate.
Eur J Vasc Endovasc Surg. 2004 Dec;28(6):583-9. doi: 10.1016/j.ejvs.2004.08.014.
9
Long-term results of arteriovenous fistulas using transposed autologous basilic vein.
Br J Surg. 2000 Jun;87(6):819-23. doi: 10.1046/j.1365-2168.2000.01435.x.
10
Radial artery-perforating vein fistula for hemodialysis.
Am J Kidney Dis. 2007 Jun;49(6):824-30. doi: 10.1053/j.ajkd.2007.02.276.