Suppr超能文献

A comparison of the expected costs of high dose rate brachytherapy using 252Cf versus 192Ir.

作者信息

Rivard Mark J, Kirk Bernadette L, Stapleford Liza J, Wazer David E

机构信息

Department of Radiation Oncology, Tufts-New England Medical Center, Tuts University School of Medicine, 750 Washington Street, Boston, MA 02111, USA.

出版信息

Appl Radiat Isot. 2004 Dec;61(6):1211-6. doi: 10.1016/j.apradiso.2004.03.113.

Abstract

A cost analysis to compare high dose rate (HDR) brachytherapy using either californium-252 (252Cf) or 192Ir was performed to determine the prospects of widespread clinical implementation of HDR 252Cf. Interest in the neutron-emitting 252Cf radioisotope as a radiotherapy nuclide has undergone a resurgence given recent efforts to fabricate HDR remotely afterloaded sources, and other efforts to create a miniature source for improved accessibility to a variety of anatomic sites. Therefore, HDR 252Cf brachytherapy may prove to be a potential rival to the use of HDR 192Ir remotely afterloaded brachytherapy--the current standard-of-care treatment modality using HDR brachytherapy. Considering the possible improvements in clinical efficacy using HDR 252Cf brachytherapy and the enormous costs of other high-LET radiation sources, the cost differences between 252Cf and 192Ir may be well-justified.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验