Suppr超能文献

使用电子射野影像装置评估乳腺癌放疗中分次内和分次间的运动

Evaluation of intra- and inter-fraction motion in breast radiotherapy using electronic portal cine imaging.

作者信息

Kron T, Lee C, Perera F, Yu E

机构信息

Integrated Cancer Program, London Health Sciences Centre and University of Western Ontario, 790 Commissioners Road East, London Ontario N6A 4L6, Canada.

出版信息

Technol Cancer Res Treat. 2004 Oct;3(5):443-9. doi: 10.1177/153303460400300505.

Abstract

Breast irradiation is one of the most challenging problems in radiotherapy due to the complex shape of the target volume, proximity of radiation sensitive normal structures and breathing motion. It was the aim of the present study to use electronic portal imaging (EPI) during treatment to determine intra- and inter-fraction motion in patients undergoing radiotherapy and to correlate the magnitude of motion with patient specific parameters. EPI cine images were acquired from the medial tangential fields of twenty radiotherapy patients on a minimum of 5 days each over the course of their treatment. The treatments were administered using 10 MV X-rays and dynamic wedges on a Varian Clinac 2100CD linear accelerator. Depending on the incident dose and the angle of the wedge, between 4 and 16 images could be acquired in one session using an EPI device based on liquid ionization chambers (Varian). The border between lung and chest-wall could be easily detected in all images and quantitative measurements were taken for the amount of lung in the field and the distance of the breast tissue from the field edges. Inter-fraction variability was found to be about twice as large as intra-fraction variability. The largest variability was detected in cranio/caudal direction (intra-fraction: 1.3 +/- 0.4 mm; inter-fraction: 2.6 +/- 1.3 mm) while the lung involvement varied by 1.1 +/- 0.2 mm and 1.8 +/- 0.6 mm intra- and inter-fraction, respectively. This indicates that the effect of breathing motion on the amount of radiated lung was not of major concern in the patients studied. Of other patient specific parameters such as body weight, breast separation, field size and location of the target, only increasing age was significantly correlated with larger inter-fraction motion. Acquisition of EPI cine loops proved to be a quick and easy technique to establish the amount of patient movement during breast radiotherapy. The relatively small variability found in the present pilot study justifies considerations for more conformal dose delivery.

摘要

由于靶区形状复杂、存在对辐射敏感的正常组织以及呼吸运动,乳腺放疗是放射治疗中最具挑战性的问题之一。本研究的目的是在治疗过程中使用电子射野影像(EPI)来确定接受放疗患者的分次内和分次间运动,并将运动幅度与患者的特定参数相关联。在20名放疗患者的内侧切线野上,在其治疗过程中至少连续5天采集EPI电影图像。治疗使用10 MV X射线和Varian Clinac 2100CD直线加速器上的动态楔形板进行。根据入射剂量和楔形板角度,使用基于液体电离室的EPI设备(Varian)在一次采集中可以采集4至16幅图像。在所有图像中都能轻松检测到肺与胸壁之间的边界,并对野内肺的量以及乳腺组织距野边缘的距离进行了定量测量。发现分次间变异性约为分次内变异性的两倍。在头/尾方向检测到最大变异性(分次内:1.3±0.4 mm;分次间:2.6±1.3 mm),而肺受累在分次内和分次间分别变化1.1±0.2 mm和1.8±0.6 mm。这表明在所研究的患者中,呼吸运动对辐射肺量的影响并非主要问题。在其他患者特定参数,如体重、乳腺间距、野大小和靶区位置中,只有年龄增加与较大的分次间运动显著相关。事实证明,采集EPI电影环是一种快速简便的技术,可用于确定乳腺放疗期间患者的运动量。本初步研究中发现的相对较小的变异性为考虑更适形的剂量递送提供了依据。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验