Rasquinha Vijay J, Ranawat Chitranjan S, Dua Vipul, Ranawat Amar S, Rodriguez Jose A
Ranawat Orthopaedic Center, Department of Orthopaedic Surgery, Lenox Hill Hospital, New York, New York 10021, USA.
J Arthroplasty. 2004 Oct;19(7 Suppl 2):2-9. doi: 10.1016/j.arth.2004.06.005.
This prospective randomized double-blind study aims to evaluate the effect of surface finish of the cemented femoral stem in primary total hip arthroplasty. Between January 1996 and May 1997, a single surgeon prospectively implanted 244 primary THAs (237 patients) using cemented femoral stems with modified third-generation cement technique in selected patients. Patients were randomized to receive the Ranawat-Burstein prosthesis (Biomet, Warsaw, IN) with 1 of 2 finishes (smooth-Ra 17 or rough-Ra 170). At a minimum 5-year follow-up, no statistical differences were found between the 2 groups. One patient with a smooth stem underwent revision of the femoral component at 2 years secondary to aseptic loosening. There was no other evidence of radiographic loosening or osteolysis. As an isolated variable, surface finish does not appear to significantly influence results at mean follow-up of 6.5 years.
这项前瞻性随机双盲研究旨在评估初次全髋关节置换术中骨水泥型股骨柄表面光洁度的影响。1996年1月至1997年5月期间,一名外科医生前瞻性地为选定患者使用改良第三代骨水泥技术的骨水泥型股骨柄植入了244例初次全髋关节置换术(237名患者)。患者被随机分配接受Ranawat-Burstein假体(Biomet,华沙,印第安纳州),其表面光洁度有两种(光滑-Ra 17或粗糙-Ra 170)。在至少5年的随访中,两组之间未发现统计学差异。一名使用光滑柄的患者在2年时因无菌性松动接受了股骨部件翻修。没有其他影像学松动或骨溶解的证据。作为一个独立变量,在平均6.5年的随访中,表面光洁度似乎不会显著影响结果。